2016 IEEE International Telecommunications Energy Conference (INTELEC) 2016
DOI: 10.1109/intlec.2016.7749138
|View full text |Cite
|
Sign up to set email alerts
|

Approach and basic evaluation for the DC circuit breaker with fault current limiting feature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…A current limiting DC CB is capable of limiting fault current or its RoR. The fault current limiting at different voltage levels can be performed using a driver circuit for semiconductor switches for a limited time interval [147]. The fault current limiter can be used in DC CBs for HVDC grid applications, as well.…”
Section: Other Types Of DC Circuit Breakersmentioning
confidence: 99%
“…A current limiting DC CB is capable of limiting fault current or its RoR. The fault current limiting at different voltage levels can be performed using a driver circuit for semiconductor switches for a limited time interval [147]. The fault current limiter can be used in DC CBs for HVDC grid applications, as well.…”
Section: Other Types Of DC Circuit Breakersmentioning
confidence: 99%
“…The review and discussion of the top 120 most cited papers were discussed, and it was discovered that the majority of the articles published in recent years focused on the development of protection schemes or control systems for fault detection to enable faster fault clearing, and automatic and quick recovery. Various approaches and methods have been developed for the implementation of solid state protection so that operation can be accomplished safely, quickly, at a lower cost and loss with increased long-term dependability interruption fault current switching [38,[41][42][43][44][45][46][47][48][49]. Prototyping for interruption of faults has recently been completed and experimentally demonstrated the presence of interruptions [46,[50][51][52][53][54][55][56][57][58].…”
Section: Publication Trends and Citation Structuresmentioning
confidence: 99%
“…Further investigation is required to address against short circuits under low voltage distribution in microgrid applications. SSCBs based on silicon IGBTs or IGCTs [41,46,58,64,73,77,83,84,91,101,126] and thyristors [41,46,58,64,73,77,83,91,101,126], as main static switches were reported. SSCB implementation is the second most frequently studied topic (see Table 4).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, it is necessary to jointly consider the breaking capability of the DC breaker and the current limiting measure of the system, which means that the fault current should be limited to the DC breaker's breaking capability. Domestic and foreign scholars have carried out related research on the fault clearing strategy of DC breakers [18][19][20][21]. The current researches are mostly about the design of the current limiting module, while the current limiting method and scheme from a systematic perspective are not proposed.…”
Section: Introductionmentioning
confidence: 99%