2018
DOI: 10.1007/s11356-018-3298-y
|View full text |Cite
|
Sign up to set email alerts
|

Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 21 publications
0
5
0
1
Order By: Relevance
“…The microorganisms may form colonies, resulting in biofilm formation in the tubing wall of DUWLS (9). Additionally, concerns were raised about the health risks posed by the contaminated water in the DUWLS, even before the pandemic (10,11). A significant quantity of microorganisms was detected in the sample water collected from the DUWLS, indicating that the water used during dental procedures was not sterile (12).…”
Section: Research Toolmentioning
confidence: 99%
“…The microorganisms may form colonies, resulting in biofilm formation in the tubing wall of DUWLS (9). Additionally, concerns were raised about the health risks posed by the contaminated water in the DUWLS, even before the pandemic (10,11). A significant quantity of microorganisms was detected in the sample water collected from the DUWLS, indicating that the water used during dental procedures was not sterile (12).…”
Section: Research Toolmentioning
confidence: 99%
“…Additionally, the cup position, the adequacy of the quantity of the water supply, and the water supply speed are important. Furthermore, water purification and wastewater treatment facilities are essential for a pleasant environment and the prevention of cross infection [ 18 , 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…Standard precautions should be undertaken to monitor and maintain clean dental unit waterlines with <500 colony-forming units (CFU) per milliliter as recommended by the CDC [ 13 ]. Suggested measures include removal of retracted materials from rotary and ultrasonic instruments as well as air-water syringes, regular disinfection of the suction lines and DWL to remove bacterial biofilm, and use of sterile water to perform procedures [ 13 , 23 25 ]. The National Guidelines for the Control of Legionellosis in Ireland recommends undertaking of Legionella annual assessment on the risk of Legionella infection from DWL [ 26 ].…”
Section: Introductionmentioning
confidence: 99%
“…A laxity in the compliance to infection control and preventive measures by some DHCP has been reported all over the world; hence, evaluation of infection control practices and associated factors is worthwhile [ 23 , 31 – 34 ]. Furthermore, occasional disease outbreaks and pandemics justify review of routine guidelines as well as issuing updates and promoting stringent adherence in order to protect the DHCP and their patients.…”
Section: Introductionmentioning
confidence: 99%