2020
DOI: 10.4324/9781003018414
|View full text |Cite
|
Sign up to set email alerts
|

Applied Structural Equation Modeling Using AMOS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
356
0
11

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 488 publications
(512 citation statements)
references
References 0 publications
4
356
0
11
Order By: Relevance
“…The final measurement scale consisted of 26 items established to measure teachers' perception of school climate. The overall scale had the coefficient alpha value of .96, which indicated an excellent internal consistency among items based on guiding rules suggested by Collier (2020) and Kline (2016).…”
Section: Instrumentmentioning
confidence: 79%
“…The final measurement scale consisted of 26 items established to measure teachers' perception of school climate. The overall scale had the coefficient alpha value of .96, which indicated an excellent internal consistency among items based on guiding rules suggested by Collier (2020) and Kline (2016).…”
Section: Instrumentmentioning
confidence: 79%
“…As Collier (2020) points out, normed chi-square value (χ2/df) less than 3 indicates a good model fit. In addition, a substantial body of literature has documented that the value of .90 or above shows acceptable level for GFI, NFI, RFI, TLI, CFI and IFI (Collier, 2020;Hair et al, 2019;Ho, 2006;Schumacker & Lomax, 2016). Likewise, RMSEA value below .08 and SRMR value below .05 indicate a good model fit (Collier, 2020;Schumacker & Lomax, 2016).…”
Section: Confirmatory Factor Analysis-measurement Model Testmentioning
confidence: 99%
“…In addition, a substantial body of literature has documented that the value of .90 or above shows acceptable level for GFI, NFI, RFI, TLI, CFI and IFI (Collier, 2020;Hair et al, 2019;Ho, 2006;Schumacker & Lomax, 2016). Likewise, RMSEA value below .08 and SRMR value below .05 indicate a good model fit (Collier, 2020;Schumacker & Lomax, 2016). CFA results for initial measurement model showed the normed chi-square test (χ2/df) value of 3.67, GFI value of .73, NFI value of.83, RFI value of .82, TLI value of .86, CFI value of .87, IFI value of .87, RMSEA value of .08 and SRMR value of .05.…”
Section: Confirmatory Factor Analysis-measurement Model Testmentioning
confidence: 99%
See 1 more Smart Citation
“…Ukuran sampel minimum penelitian ini mengikuti perhitungan berdasarkan kekuatan, ukuran efek yang diinginkan, dan kompleksitas model (Collier, 2020) menggunakan kalkulator online Soper (2020) dengan parameter ukuran efek 0.3, level kekuatan 0.8, jumlah variabel laten 13, jumlah indikator 66, dan level probabilitas 0.05. Hasil kalkulasi menunjukkan jumlah sampel minimum yang direkomendasikan adalah 204.…”
Section: Pengumpulan Dataunclassified