Applications of quantum cascade lasers for sensitive trace gas measurements of CO, CH4, N2O and HCHO

Abstract: We describe here a sensitive quantum cascade laser absorption spectrometer (QCLAS) employed for aircraft based measurements during the GABRIEL 2005 and HOOVER 2006 and 2007 campaigns. This 3-channel instrument measures CO, HCHO, CH4 and N2O using a 64-m path double corner cube White cell. Performance of the instrument was examined for the four species and precisions for CO, N2O and CH4 were measured in the field to be 0.5, 0.5 and 0.7% respectively (2σ). The 1σ detection limit for HCHO was ∼500 pptv for a 2 s … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
65
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 67 publications
(66 citation statements)
references
References 26 publications
1
65
0
Order By: Relevance
“…All in situ measurements used here are based on a data set with a 10 s time resolution, which is available from the HALO database (https://halo-db.pa.op.dlr.de). The corresponding measurement techniques are described in the accompanying paper and in more detail in publications about the individual instruments: CO (Hoor et al, 2004;Schiller et al, 2008;Müller et al, 2016), HCl Voigt et al, 2014), NO/NO y (Ziereis et al, 2000) and O 3 . Among those tracers, only HCl mixing ratios were at the instrument's detection limit during the considered flight .…”
Section: Datamentioning
confidence: 99%
“…All in situ measurements used here are based on a data set with a 10 s time resolution, which is available from the HALO database (https://halo-db.pa.op.dlr.de). The corresponding measurement techniques are described in the accompanying paper and in more detail in publications about the individual instruments: CO (Hoor et al, 2004;Schiller et al, 2008;Müller et al, 2016), HCl Voigt et al, 2014), NO/NO y (Ziereis et al, 2000) and O 3 . Among those tracers, only HCl mixing ratios were at the instrument's detection limit during the considered flight .…”
Section: Datamentioning
confidence: 99%
“…The 1-sigma total uncertainty values were calculated to be 1.10 % for CO, 0.57 % for CH 4 and 8.56 % for HCHO. We refer to Schiller et al (2008) for more details on the different methods that were used to calculate the DL for TRISTAR and for an in depth description of the instrument and its performance during HOOVER.…”
Section: Measurements Of H 2 O 2 and Ch 3 Ooh *mentioning
confidence: 99%
“…The TRIHOP instrument is a three-channel Quantum Cascade Laser Infrared Absorption spectrometer (QCLAS) capable of the subsequent measurement of CO, CO 2 , CH 4 , and N 2 O (Schiller et al, 2008;Müller et al, 2016). The instrument applies QCLAS in the mid-infrared with a multipass absorption cell (type White), which is kept at a constant pressure of p = 30 hPa and has a path length of 64 m and a volume of 2.7 L. During TACTS/ESMVal the instrument is in situ calibrated approx.…”
Section: Trihopmentioning
confidence: 99%