2008
DOI: 10.1007/s10008-008-0582-7
|View full text |Cite
|
Sign up to set email alerts
|

Applications of nanostructured Pt-Au hybrid film for the simultaneous determination of catecholamines in the presence of ascorbic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 36 publications
0
8
0
Order By: Relevance
“…They are, the nano-Au self assembled GCE for selective determination of epinephrine in the presence of ascorbic acid [16], nanostructured Pt-Au hybrid film for simultaneous determination of catecholamines in the presence of ascorbic acid [17], DNA combined gold nanoparticle multi layer films for selective determination of norepinephrine in presence of AA [18], boron-doped diamond electrode modified with gold nanoparticles/polyelectrolyte-coated polystyrene colloids [19], nano-Au self-assembly on GCE [20], and ferrocene encapsulated Pd-linked ormosil based biosensor for the dopamine detection process [21], respectively.…”
Section: Introductionmentioning
confidence: 99%
“…They are, the nano-Au self assembled GCE for selective determination of epinephrine in the presence of ascorbic acid [16], nanostructured Pt-Au hybrid film for simultaneous determination of catecholamines in the presence of ascorbic acid [17], DNA combined gold nanoparticle multi layer films for selective determination of norepinephrine in presence of AA [18], boron-doped diamond electrode modified with gold nanoparticles/polyelectrolyte-coated polystyrene colloids [19], nano-Au self-assembly on GCE [20], and ferrocene encapsulated Pd-linked ormosil based biosensor for the dopamine detection process [21], respectively.…”
Section: Introductionmentioning
confidence: 99%
“…The linear range of response and limit of detection were analyzed in comparison to electrochemical sensors to adrenaline reported in the literature (Table 1). [39][40][41][42][43][44][45][46][47][48][49][50][51] As can be seen, the BEDT-TTF/DNA/TiO 2 /ITO photoelectroanalytical sensor shows a linear range of response of four orders of magnitude and a limit of detection of 1 nmol L -1 , which were as good as the best electrochemical sensors to adrenaline. The precision of measurements using the BEDT-TTF/DNA/TiO 2 /ITO photoelectroanalytical sensor was investigated from intra-day and inter-day repeatability studies.…”
Section: Optimization Of the Bedt-ttf/dna/tio 2 Photoelectroanalyticamentioning
confidence: 68%
“…A gold nanoparticle-doped DNA composite electrode has been used for the detection of norepinephrine in the presence of ascorbic acid (Lu 2004). A nanostructured platinum-gold (Pt–Au) hybrid film modified glassy carbon electrode fabricated by electro-deposition (Thiagarajan 2009) was able to detect both epinephrine and norepinephrine individually and in the presence of ascorbic acid. Simultaneous determination of epinephrine and norepinephrine was investigated by square wave voltammetry using multi-walled carbon nanotubes modified edge plane pyrolytic graphite electrode (Goyal 2011).…”
Section: Electrochemical Detection Of Monoamine Neurotransmittersmentioning
confidence: 99%