Contemporary Practice in Clinical Chemistry 2020
DOI: 10.1016/b978-0-12-815499-1.00021-1
|View full text |Cite
|
Sign up to set email alerts
|

Applications of mass spectrometry in the clinical laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 45 publications
0
3
0
Order By: Relevance
“…Selected ion monitoring mode was used to estimate the CEE traces with high‐quality precision and sensitivity. Atmospheric pressure chemical ionization, which is similar to electrospray ionization technique, was chosen for the CEE estimation, as it worked effectively for the estimation of small and liquid molecules with lower polarities (Colby & Thoren, 2020; Lee et al, 2015; Thomas, 2019). A drying temperature of 250°C and a vaporization temperature of 400°C were applied to de‐solvate the buffer rapidly into aerosol droplets in a stream of nitrogen gas.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Selected ion monitoring mode was used to estimate the CEE traces with high‐quality precision and sensitivity. Atmospheric pressure chemical ionization, which is similar to electrospray ionization technique, was chosen for the CEE estimation, as it worked effectively for the estimation of small and liquid molecules with lower polarities (Colby & Thoren, 2020; Lee et al, 2015; Thomas, 2019). A drying temperature of 250°C and a vaporization temperature of 400°C were applied to de‐solvate the buffer rapidly into aerosol droplets in a stream of nitrogen gas.…”
Section: Resultsmentioning
confidence: 99%
“…Selected ion monitoring mode was used to estimate the CEE traces with high-quality precision and sensitivity. Atmospheric pressure chemical ionization, which is similar to electrospray ionization technique, was chosen for the CEE estimation, as it worked effectively for the estimation of small and liquid molecules with lower polarities (Colby & Thoren, 2020;Lee et al, 2015;Thomas, 2019). A drying tem- As shown in Table 2, various trials were carried out by changing the nebulizer gas (N 2 ) pressure, drying gas (N 2 ) flow rate, drying gas (N 2 ) temperature and vaporizer temperature, but all of the changes made, except for the nebulizer gas pressure, under ionization parameters did not have any influence on the detection and estimation of CEE.…”
Section: Selection Of Ionization Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, there are major challenges and legal issues related to MS adoption because these assays are primarily laboratory-developed diagnostics. 7…”
Section: Discussionmentioning
confidence: 99%