2018
DOI: 10.1016/j.envint.2018.04.018
|View full text |Cite
|
Sign up to set email alerts
|

Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone?

Abstract: Over the past decade, a range of sensor technologies became available on the market, enabling a revolutionary shift in air pollution monitoring and assessment. With their cost of up to three orders of magnitude lower than standard/reference instruments, many avenues for applications have opened up. In particular, broader participation in air quality discussion and utilisation of information on air pollution by communities has become possible. However, many questions have been also asked about the actual benefi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
432
0
8

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 555 publications
(449 citation statements)
references
References 81 publications
(121 reference statements)
9
432
0
8
Order By: Relevance
“…This section discusses various analyses done on the data collected during the considered deployment. Although a single manufacturer developed the PM sensors that were used in the studied Atmos boxes, their performance in measuring PM 10 has not yet been tested in field conditions. First, we checked the sensors for consistency, and then we deployed them in the field next to the inlets of different research-grade PM measuring instruments.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…This section discusses various analyses done on the data collected during the considered deployment. Although a single manufacturer developed the PM sensors that were used in the studied Atmos boxes, their performance in measuring PM 10 has not yet been tested in field conditions. First, we checked the sensors for consistency, and then we deployed them in the field next to the inlets of different research-grade PM measuring instruments.…”
Section: Resultsmentioning
confidence: 99%
“…Total numbers of hourly averaged data points at MRIU, Faridabad from SMPS-OPS, Atmos PM sensor, and SMPS-APS were 717, 1124, and 766, respectively. The overall mean PM 10 After collecting sufficient PM10 data during the deployment period of 21 January 2018-16 March 2018, time series were plotted for the two study sites, as shown in Figure 4a The total number of hourly averaged data points at IITD, New Delhi from SMPS-OPS and the Atmos PM sensor was 832 and 1029, respectively. Mean PM10 concentrations measured by SMPS-OPS and Atmos were 182.3 ± 84.2 μg•m −3 and 181.0 ± 111.5 μg•m −3 , respectively.…”
Section: Time Series Of Measured Pm 10 Concentrationsmentioning
confidence: 99%
See 2 more Smart Citations
“…Several researchers adopted their own calibration and evaluation procedures to test the low-cost sensors including co-location measurements in ambient environment and lab-scale measurements using standard test particles or ambient airborne particles. 15,18,[20][21][22][23][24][25] However, the accuracy of measurement data has always been questioned by many researchers and scientists, 15,26,27 and the limited number of sensors have been assessed due to the time-consuming evaluation process, which might not be able to represent the overall performance of hundreds of low-cost sensors in the commercial market. Besides, the lack of standardized methods for performance evaluation of low-cost sensors results in difficulties in intercomparisons of the sensors evaluated in different studies.…”
mentioning
confidence: 99%