1995
DOI: 10.1016/0019-0578(94)00041-j
|View full text |Cite
|
Sign up to set email alerts
|

Applications of automatic control systems for chlorination and dechlorination processes in wastewater treatment plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…This change is proportional to changes in the respiration rate, if changes in DO concentration inside the reactor due to incoming and outgoing flows are negligible. The respiration rate is estimated as the slope of a regression line fitted to a series of DO signals (Carlsson et al, 1994;Dieu et al, 1995;Johansen et al, 1997;Sotomayor et al, 2002). However, because the relay-feedback method may experience an unexpected disturbance during the identification, the process variables may deviate from the normal steady state during the identification step.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…This change is proportional to changes in the respiration rate, if changes in DO concentration inside the reactor due to incoming and outgoing flows are negligible. The respiration rate is estimated as the slope of a regression line fitted to a series of DO signals (Carlsson et al, 1994;Dieu et al, 1995;Johansen et al, 1997;Sotomayor et al, 2002). However, because the relay-feedback method may experience an unexpected disturbance during the identification, the process variables may deviate from the normal steady state during the identification step.…”
Section: Resultsmentioning
confidence: 99%
“…At the same time, DO level cannot be controlled satisfactorily with a simple PID controller because the DO level depends on time-varying influent loads, time delays, sensor noise and slow dynamics, temperature, and the activity of microorganisms. Many real-time identification methods have been proposed for obtaining process information (Åströ m and Hä gglund, 1984;Dieu et al, 1995;Yoo et al, 2001). Carlsson et al (1994) used the autotuning controller suggested by Åströ m-Hä gglund to control the DO concentration in a WWTP.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Mathematical modeling and implementation with artificial neural networks Dieu, Garrett Jr., Ahmad, and Young (1995) proposed a single variable Proportional-Integral-Derivative (PID) chlorine control dosage, with all the required devices, such as online analyzer free residual chlorine, PLCs and chlorine dosers, demonstrating a control loop similar to that used in WTP under analysis. Since the WTP postchlorination dosage has several variables that directly impact the FRC rate in the treated water, the use of the traditional PID controller is restricted, as reported by Escobar and Trierweiler (2013).…”
Section: Problem Descriptionmentioning
confidence: 99%