Applications and properties of the Bijvoet intensity ratio

Abstract: An empirical relationship of use in prediction and evaluation is established between the standard uncertainty of the Flack parameter and the Bijvoet intensity ratio. The expected value of this ratio may be calculated from the chemical composition of the compound and the X-ray wavelength. Structure analyses published with intensity data have allowed various properties of the Bijvoet intensity ratio to be studied. It is found that, although the Bijvoet intensity ratio has a strong dependence on sin theta/lambda,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(29 citation statements)
references
References 21 publications
(25 reference statements)
1
28
0
Order By: Relevance
“…Then, Friedif-centro = 195 for (I)-LT (Cu K radiation) and 123 for (II)-LT (Mo K radiation). The corresponding standard uncertainties would be 0.041 and 0.065 (Flack et al, 2006;Flack & Bernardinelli, 2008). The refined values of the Flack (1983) parameter converged to 0.504 (15) and 0.41 (13) for (I)-LT and (II)-LT, respectively.…”
Section: Figure 16mentioning
confidence: 96%
See 2 more Smart Citations
“…Then, Friedif-centro = 195 for (I)-LT (Cu K radiation) and 123 for (II)-LT (Mo K radiation). The corresponding standard uncertainties would be 0.041 and 0.065 (Flack et al, 2006;Flack & Bernardinelli, 2008). The refined values of the Flack (1983) parameter converged to 0.504 (15) and 0.41 (13) for (I)-LT and (II)-LT, respectively.…”
Section: Figure 16mentioning
confidence: 96%
“…Because of the presence of the pseudo-inversion centres that link every second molecule, a half of the content of the unit cell can be considered as centrosymmetric and, as a consequence, would lower the value of Friedif. Then the value of Friedif-centro (Flack & Bernardinelli, 2008) would be 465 for (I)-LT (Cu K radiation) and 284 for (II)-LT (Mo K radiation). However, the other set of inversion centres ( 3 4 , 0.1, 3 4 etc., see text above) is present in the structure, which would also decrease the value of Friedif-centro.…”
Section: Figure 11mentioning
confidence: 99%
See 1 more Smart Citation
“…Details of the relevant intensity measurements, structure refinement and data analysis for 1,3,4,6-tetra-Oacetyl-2-(trifluoromethylsulfonyl)-d-mannopyranose (Zhu & Jiang, 2007) (CSD refcode: UNEVAK01) are given in Flack & Bernardinelli (2008) …”
Section: Status Of Centrosymmetry and Resonant Scatteringmentioning
confidence: 99%
“…Until date there have been several spectroscopic, diffraction methods developed to determine the absolute stereostructure of chiral molecules [2635]. The non-empirical methods employed to determine the absolute configuration of a molecule include circular dichroism, exciton chirality methods [28–29], NMR spectroscopy [3032], X-ray diffraction [3335], etc.…”
Section: Introductionmentioning
confidence: 99%