Applications and limitations of constrained high-resolution peak fitting on low resolving power mass spectra from the ToF-ACSM

Abstract: Abstract. The applicability, methods and limitations of constrained peak fitting on mass spectra of low mass resolving power (m∕Δm50 ∼ 500) recorded with a time-of-flight aerosol chemical speciation monitor (ToF-ACSM) are explored. Calibration measurements as well as ambient data are used to exemplify the methods that should be applied to maximise data quality and assess confidence in peak-fitting results. Sensitivity analyses and basic peak fit metrics such as normalised ion separation are employed to demonst… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
31
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(32 citation statements)
references
References 41 publications
(85 reference statements)
1
31
0
Order By: Relevance
“…A description of the algorithm can be found in Stark et al 2015and Timonen et al (2016). Figure 1 shows the high-resolution peak fitting to the averaged mass spectra on a typical day (12 October 2018) for m/z 169, m/z 211 and m/z 281, at which masses produced by dodecane (C12H25 + ), pentadecane (C15H31 + ) and eicosane (C20H41 + ) are detected.…”
Section: No + Ptr-tof-ms Measurementsmentioning
confidence: 99%
“…A description of the algorithm can be found in Stark et al 2015and Timonen et al (2016). Figure 1 shows the high-resolution peak fitting to the averaged mass spectra on a typical day (12 October 2018) for m/z 169, m/z 211 and m/z 281, at which masses produced by dodecane (C12H25 + ), pentadecane (C15H31 + ) and eicosane (C20H41 + ) are detected.…”
Section: No + Ptr-tof-ms Measurementsmentioning
confidence: 99%
“…Submicron particle non-refractory species, such as organics, nitrate, sulfate, ammonium, and chloride, were monitored on a basis of 10-min time resolution using the aerosol chemical speciation monitor (ACSM, Aerodyne Research Inc, USA) and the time-of-flight ACSM (ToF-ACSM, Aerodyne Research Inc., USA). Extensive descriptions of the instruments are presented by Ng et al (2011), Fröhlich et al (2013, and Timonen et al (2016).…”
Section: Aerosol Mass Spectrometrymentioning
confidence: 99%
“…Although there is not yet a quantitative method to determine the extent and magnitude of peak overlap errors in every situation, Tofware provides qualitative assessment tools that rely on the dependence of peak-fitting error on mass calibration precision (Timonen et al, 2016). Several studies have suggested that mass calibration precision and accuracy are strong controls on peak fitting error (Corbin et al, 2015;Cubison and Jimenez, 2015).…”
Section: S1 Peak Fitting Errors: Data Quality Assessmentmentioning
confidence: 99%