2009
DOI: 10.1109/tdei.2009.4784570
|View full text |Cite
|
Sign up to set email alerts
|

Application possibilities of artificial neural networks for recognizing partial discharges measured by the acoustic emission method

Abstract: The genesis of the research work presented in this paper constitutes the issue of the effective and efficient recognition of single-source one-time partial discharge forms that can occur in insulation systems of power transformers. The paper presents research results referring to the use of single-direction artificial neural networks for recognizing basic partial discharge forms that can occur in paper-oil insulation impaired by aging processes. The research work results presented show the recognition effectiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 82 publications
(38 citation statements)
references
References 23 publications
0
37
0
1
Order By: Relevance
“…The measurement chain consists of the following elements: wideband measurement transducer WD, type AH 17, preamplier type 2/4/6 from PAC, broadband amplier of type AE2A, a 12-bit measurement card type CH-3160, and industry PC. Detailed description of the measurement chain and the procedures used for processing and analyzing the recorded signals are presented in [1,7,10]. …”
Section: Methodology Of Measurements Performed In the Studymentioning
confidence: 99%
“…The measurement chain consists of the following elements: wideband measurement transducer WD, type AH 17, preamplier type 2/4/6 from PAC, broadband amplier of type AE2A, a 12-bit measurement card type CH-3160, and industry PC. Detailed description of the measurement chain and the procedures used for processing and analyzing the recorded signals are presented in [1,7,10]. …”
Section: Methodology Of Measurements Performed In the Studymentioning
confidence: 99%
“…For this reason, detecting partial discharge is useful for the insulation assessment and to predict the life of the insulation [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…The non-contact method usually uses chemical transformation, gas pressure, heat, light and acoustic emission. However, only the last two are considered as practically important [15]. In order to provide the accurate solution, it is vital to identify the PD type first.…”
Section: Introductionmentioning
confidence: 99%
“…The application of the acoustic emission method for the diagnosis of power transformers makes it possible to assess the technical condition of these appliances during their regular live operation, which is, undoubtedly, its advantage (Boczar et al, 2009;Cichoń, 2009;Kundu et al, 2008;Skubis et al, 2009). The essential application of this method is the possibility of detection of partial discharges occurring in the internal insulation system of the appliance.…”
Section: Introductionmentioning
confidence: 99%