Application of Voltage Harmonic Distortion Positive Feedback for Islanding Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Power mismatches between source and load during islanding conditions lead to harmonic distortions that are calculated by THD. It is a signal‐harmonic distortion measurement strategy being specified as the proportion of the total harmonic component and the basic frequency and typically a percentage value 70 . If the parameter being monitored and surpasses the set limit value, the DG must be disconnected from the inverter 71 .…”
Section: Islanding Detection Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Power mismatches between source and load during islanding conditions lead to harmonic distortions that are calculated by THD. It is a signal‐harmonic distortion measurement strategy being specified as the proportion of the total harmonic component and the basic frequency and typically a percentage value 70 . If the parameter being monitored and surpasses the set limit value, the DG must be disconnected from the inverter 71 .…”
Section: Islanding Detection Methodsmentioning
confidence: 99%
“…It is a signal-harmonic distortion measurement strategy being specified as the proportion of the total harmonic component and the basic frequency and typically a percentage value. 70 If the parameter being monitored and surpasses the set limit value, the DG must be disconnected from the inverter. 71 Nevertheless, choosing a trip threshold is not easy, as the distortion level of the nonlinear load…”
Section: Passive Idmsmentioning
confidence: 99%
“…Passive methods include any system that attempts to detect transient changes on the grid, and then uses that information as the basis to determine a probable failure of the grid or a temporary change . Under voltage/over voltage (UV/OV) , rate of change of frequency (ROCOF) , vector surge relay technique (VS) , under frequency/over frequency (UF/OF) , voltage phase jump (VPJ) , voltage harmonic distortion , and total harmonic distortion (THD) are a few examples of passive islanding detection techniques. In the case of correct operation of the protective relay, the relay should be set by considering upper and lower threshold values.…”
Section: Introductionmentioning
confidence: 99%
“…In addit ion, the said scheme takes longer time (more than 0.85s) to detect islanding conditions in a large power distribution network with mu ltip le DG. Jing et al [35] proposed islanding detection scheme based on the positive feedback of voltage harmonics distortion. Later on, Samui et al [36] proposed wavelet singular entropy based islanding detection technique for lower power mis matches.…”
Section: (C)mentioning
confidence: 99%