2018
DOI: 10.1002/mp.13306
|View full text |Cite
|
Sign up to set email alerts
|

Application of variance‐based uncertainty and sensitivity analysis to biological modeling in carbon ion treatment plans

Abstract: Purpose In ion beam therapy, biological models to estimate the relative biological effectiveness (RBE) and subsequently the RBE‐weighted dose (RWD) are needed in treatment planning and plan evaluation. The required biological parameters as well as their dependency on ion species and ion energy can typically not be determined directly in experiments for in vivo situations. For that reason they are often derived from in vitro data and biological modeling and subject to large uncertainties. We present a model‐ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 40 publications
(81 reference statements)
0
8
0
Order By: Relevance
“…RBE modeling is frequently considered to be subject to large uncertainties, depending on the accuracy with which the model input parameters are known [114]. However, one has to keep in mind that similar uncertainties need to be considered in conventional photon therapy when e.g.…”
Section: B Biological Aspectsmentioning
confidence: 99%
“…RBE modeling is frequently considered to be subject to large uncertainties, depending on the accuracy with which the model input parameters are known [114]. However, one has to keep in mind that similar uncertainties need to be considered in conventional photon therapy when e.g.…”
Section: B Biological Aspectsmentioning
confidence: 99%
“…During dose calculation, the algorithm has to select the correct neighbor raytracing to replace based on the lateral offsets and from equation 15and * ∆ ∆ (16). This method is similar to the "virtual beamlets" approach proposed by Unkelbach et al 38 , with the difference, that in our approach only the raytracing is approximated by the neighbor which is closest to the patient shift, while the lateral part in equation 12is modeled exactly according to equations (15) and (16). The approach to keep pre-calculated neighboring raytracings for every PBS spot is memory intensive, however, since only small setup-errors are expected and need to be treated in the SA, sets of only a few shifts of up to a few millimeters are sufficient.…”
Section: Accepted Articlementioning
confidence: 99%
“…A rapid implementation 25,26 of this model in the ij-formalism for carbon ions has already been used for a variance-based SA of biological uncertainties by Kamp et al 15 and for RWD optimization by Guan et al 40 .…”
Section: C1 Rmf Modelmentioning
confidence: 99%
See 2 more Smart Citations