Abstract:Abstract-An innovative self-heat recuperation technology, in which not only latent heat but also sensible heat is circulated in the thermal process, was studied and applied to the deisobutanizer column. To determine the amount of energy required for this technology, ASPEN HYSYS was used. According to the simulation of the proposed sequence, the condenser duty and reboiler duty were saved up to 73.43 and 83.48%, respectively as compared to conventional column.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.