2007 Power Conversion Conference - Nagoya 2007
DOI: 10.1109/pccon.2007.373088
|View full text |Cite
|
Sign up to set email alerts
|

Application of Series Type BTB Converter for Minimizing Circulating Current and Balancing Power Transformers in Loop Distribution Lines

Abstract: A method for minimizing circulating current and balancing power transformer in loop distribution line of an industrial park is proposed. The proposed method uses a series type Back-To-Back (BTB) converter in loop distribution line of industrial park. Loop distribution line is formed by tying end of two radial lines by a looping wire. Looping wire has a re-closer circuit breaker to localize fault inside loop. Operation of the circuit breaker depends on the zero sequence voltage and current detection of series t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 3 publications
0
10
0
1
Order By: Relevance
“…Note that with the same Leq, the circulating current will be 150A if the switching frequency is brought down to 20 kHz (see Equation [8]). To get the same circulating current value, the equivalent inductance should be increased to 10 times.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Note that with the same Leq, the circulating current will be 150A if the switching frequency is brought down to 20 kHz (see Equation [8]). To get the same circulating current value, the equivalent inductance should be increased to 10 times.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Various methods are applied to suppress the circulating current. The current path is removed either by using separate DC supplies to each inverter input [7] or by adding isolation transformers to each inverter output [8]. Increasing the impedance of the current path reduces the circulating current by adding coupled inductors (CIs) and common-mode inductors (CMIs) [9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Optimal power flow (OPF) can be treated as a nonlinear multivariable constrained optimization procedure [29], [30]. Accordingly, constraints related to the network power flows and SOP thermal limits must be considered.…”
Section: Optimization Constraintsmentioning
confidence: 99%
“…The principal functionality of a back-to-back converter is the ability to control the active power flow between two AC subsystems. An interesting application that takes advantage of this property is the PBS applied to distribution networks [12,44,45], or in MGs [46]. Fig.…”
Section: Btb Controlled With the Synchronverter Approach Working As Amentioning
confidence: 99%