2020
DOI: 10.3892/etm.2020.8862
|View full text |Cite
|
Sign up to set email alerts
|

Application of rib surface positioning ruler combined with volumetric CT measurement technique in endoscopic minimally invasive thoracic wall fixation surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 18 publications
(17 reference statements)
0
2
0
Order By: Relevance
“…With this method, the planned incision fails to account for the dynamic nature of extrathoracic anatomic landmarks including the scapula and back muscles throughout the process of patient positioning in the operating room, as well as the possibility for inadvertent fracture displacement. 18 Therefore, surgeons often find themselves extending the incision to identify and access additional fractures, and successfully complete the planned stabilization. A larger incision and longer operative time present a dilemma.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With this method, the planned incision fails to account for the dynamic nature of extrathoracic anatomic landmarks including the scapula and back muscles throughout the process of patient positioning in the operating room, as well as the possibility for inadvertent fracture displacement. 18 Therefore, surgeons often find themselves extending the incision to identify and access additional fractures, and successfully complete the planned stabilization. A larger incision and longer operative time present a dilemma.…”
Section: Discussionmentioning
confidence: 99%
“…However, the incision’s location and length are commonly selected based on static preoperative imaging with CT and three-dimensional reconstructions when available, and the surgeon’s knowledge of chest wall anatomy. With this method, the planned incision fails to account for the dynamic nature of extrathoracic anatomic landmarks including the scapula and back muscles throughout the process of patient positioning in the operating room, as well as the possibility for inadvertent fracture displacement 18 . Therefore, surgeons often find themselves extending the incision to identify and access additional fractures, and successfully complete the planned stabilization.…”
Section: Discussionmentioning
confidence: 99%