2004
DOI: 10.1111/j.1540-8159.2004.00430.x
|View full text |Cite
|
Sign up to set email alerts
|

Application of Radiofrequency Energy in Surgical and Interventional Procedures:

Abstract: During surgical and interventional procedures, interference may occur between ICDs and electrical cautery or with the application of RF energy. This may lead to the false induction of ICD therapies or could even result in device malfunction, which represents a potential perioperative hazard for the patient. This study analyzed the intraoperative interactions in 45 consecutive ICD patients in reference to different surgical and interventional procedures. A total of 33 surgical operations (general surgery [n = 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
23
0
2

Year Published

2005
2005
2019
2019

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(29 citation statements)
references
References 22 publications
4
23
0
2
Order By: Relevance
“…179 These studies varied in patient population, definition of perioperative complications, and what was done with the results of preoperative testing, including decisions about the appropriateness of proceeding with surgery. However, a consistent finding among the studies was that a low anaerobic threshold was predictive of perioperative cardiovascular complications, 171,173,177 postoperative death, 172,174,175 or midterm and late death after surgery. 174,179,180 An anaerobic threshold of approximately 10 mL O 2 /kg/ min was proposed as the optimal discrimination point, with a range in these studies of 9.9 mL O 2 /kg/min to 11 mL O 2 / kg/min.…”
Section: Exercise Stress Testing For Myocardialmentioning
confidence: 97%
See 1 more Smart Citation
“…179 These studies varied in patient population, definition of perioperative complications, and what was done with the results of preoperative testing, including decisions about the appropriateness of proceeding with surgery. However, a consistent finding among the studies was that a low anaerobic threshold was predictive of perioperative cardiovascular complications, 171,173,177 postoperative death, 172,174,175 or midterm and late death after surgery. 174,179,180 An anaerobic threshold of approximately 10 mL O 2 /kg/ min was proposed as the optimal discrimination point, with a range in these studies of 9.9 mL O 2 /kg/min to 11 mL O 2 / kg/min.…”
Section: Exercise Stress Testing For Myocardialmentioning
confidence: 97%
“…See Cardiopulmonary exercise testing has been studied in different settings, including before abdominal aortic aneurysm surgery [172][173][174]180 ; major abdominal surgery (including abdominal aortic aneurysm resection) [175][176][177] ; hepatobiliary surgery 178 ; complex hepatic resection 171 ; lung resection 181 ; and colorectal, bladder, or kidney cancer surgery. 179 These studies varied in patient population, definition of perioperative complications, and what was done with the results of preoperative testing, including decisions about the appropriateness of proceeding with surgery.…”
Section: Exercise Stress Testing For Myocardialmentioning
confidence: 99%
“…Cardioversion can have similar effects on pacemaker or ICD function. Although the probability of any of these adverse interactions occurring has fallen dramatically owing to the almost universal use of bipolar leads (which greatly reduces the probability of electromagnetic interference) and improved pacemaker and ICD design, they still may occur (442)(443)(444)(445)447).…”
Section: Intraoperative Electromagnetic Interference With Implanted Pmentioning
confidence: 98%
“…Allerdings kann der bipolare Kauter EMI nicht völlig verhindern und ist zum Schneiden nur eingeschränkt verwendbar. Obwohl es Berichte über eine sichere Anwendung von Hochfrequenzchirurgie bei ICD-Patienten gibt [32,39], besteht dennoch das Risiko einer falschen Arrhythmiedetektion und damit der Abgabe eines inadäquaten Schocks [6,34].…”
Section: Quellen Elektromagnetischer Interferenzunclassified