2022
DOI: 10.1016/j.saa.2021.120624
|View full text |Cite
|
Sign up to set email alerts
|

Application of NIR spectroscopy for rapid quantification of acid and peroxide in crude peanut oil coupled multivariate analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 41 publications
0
13
0
Order By: Relevance
“…Mazivila et al [ 27 ] applied multivariate curve resolution-alternating least squares (MCR-ALS) as a complementary chemometric model to the DD-SIMCA. Haruna et al [ 28 ] used competitive adaptive reweighted sampling-partial least squares (CARS-PLS) for the quantitative determination of acid and peroxide values in peanut oil. Zaukuu et al [ 29 ] used linear discriminant analysis (LDA) and partial least squares regression analysis (PLSR) to predict trace components, such as urea and melamine in whey protein powder.…”
Section: Spectral Data Processing Technologymentioning
confidence: 99%
“…Mazivila et al [ 27 ] applied multivariate curve resolution-alternating least squares (MCR-ALS) as a complementary chemometric model to the DD-SIMCA. Haruna et al [ 28 ] used competitive adaptive reweighted sampling-partial least squares (CARS-PLS) for the quantitative determination of acid and peroxide values in peanut oil. Zaukuu et al [ 29 ] used linear discriminant analysis (LDA) and partial least squares regression analysis (PLSR) to predict trace components, such as urea and melamine in whey protein powder.…”
Section: Spectral Data Processing Technologymentioning
confidence: 99%
“…However, this model is frequently applied to diverse data sets (full variables), which are believed to contain unuseful information, causing collinearity and potentially undermining the efficiency of the subsequent variable predictive models. 11 2.6.3. Genetic algorithm-partial least squares (GA-PLS).…”
Section: Spectral Signal Pretreatmentsmentioning
confidence: 99%
“…10 While their precision and sensitivity are commendable, they remain inappropriate due to their cumbersome nature, exorbitant cost, the requirement of skilled personnel for successful operation, prolonged sample preparation, and the use of chemicals that are unsafe to individuals and their immediate surroundings. 11,12 The difficulty has been aggravated by the fact that these techniques are perpetually inappropriate for real-time analysis. As a result, laboratories have been inundated with critical composition data, making it challenging to repeat analyses for accurate ndings.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations