2004
DOI: 10.1007/s00216-003-2193-6
|View full text |Cite
|
Sign up to set email alerts
|

Application of isotope-dilution laser ablation ICP?MS for direct determination of Pu concentrations in soils at pg�g?1 levels

Abstract: The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 68 publications
(3 citation statements)
references
References 23 publications
(34 reference statements)
0
2
0
Order By: Relevance
“…In contrast to other studies (e.g. [ 42 44 ]), where ultra-trace concentration levels of Pu isotopes in environmental samples had been determined by applying a single collector ICP-MS, a multi-collector-ICP-MS instrument was applied here, especially following the need that the isotope ratio has to be determined on short transient signals to not compromise measurement precision and accuracy of Pu isotope ratio measurements. Similar to a previous study on U, Nd and Ru/(Ru + Tc) isotope ratios [ 18 ], the standard collector block of the Nu Plasma HR multi-collector was modified for measuring 239 Pu + , 240 Pu + and 242 Pu + simultaneously with three SEMs (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…In contrast to other studies (e.g. [ 42 44 ]), where ultra-trace concentration levels of Pu isotopes in environmental samples had been determined by applying a single collector ICP-MS, a multi-collector-ICP-MS instrument was applied here, especially following the need that the isotope ratio has to be determined on short transient signals to not compromise measurement precision and accuracy of Pu isotope ratio measurements. Similar to a previous study on U, Nd and Ru/(Ru + Tc) isotope ratios [ 18 ], the standard collector block of the Nu Plasma HR multi-collector was modified for measuring 239 Pu + , 240 Pu + and 242 Pu + simultaneously with three SEMs (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Another commonly used instrument is LA-ICP-MS, which can directly analyze solid samples without dissolution. For example, Boulyga, S. F., et al [102] developed a LA-ICP-MS method to directly analyze the concentration of plutonium isotopes in soils at the pg g −1 level. The uranium hydride ion was significantly suppressed with the application of laser ablation, and a UH + /U + ratio of 1.1 × 10 −6 was obtained.…”
Section: Icp-msmentioning
confidence: 99%
“…Additionally, uniformitythe prerequisite for mutual recognitioncan be ensured. 12,13 Besides internal standardization, [14][15][16][17] solid certied reference materials (CRMs) can be used to quantify element contents in the sample. To represent the sample as good as possible, it is necessary to use a matrix matched CRM.…”
Section: Introductionmentioning
confidence: 99%