2012
DOI: 10.1007/s11814-012-0013-4
|View full text |Cite
|
Sign up to set email alerts
|

Application of iron-coated zeolites (ICZ) for mine drainage treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…Laboratory and field experiments with household zero-valent Fe filters showed similarly effective results in Bangladesh [40]. Field tests with Fe-coated zeolites showed 99% removal of As [41]. Mn-Fe oxide-coated diatomites were able to reduce iAs from >40 μg/L to <10 μg/L in a pilot field-scale study [42].…”
Section: Arsenic Chemistry Geochemistry Prevalence and Toxicitymentioning
confidence: 77%
“…Laboratory and field experiments with household zero-valent Fe filters showed similarly effective results in Bangladesh [40]. Field tests with Fe-coated zeolites showed 99% removal of As [41]. Mn-Fe oxide-coated diatomites were able to reduce iAs from >40 μg/L to <10 μg/L in a pilot field-scale study [42].…”
Section: Arsenic Chemistry Geochemistry Prevalence and Toxicitymentioning
confidence: 77%
“…For example, a zeolite from Greece had Langmuir adsorption capacities (mg/g) of 3.5, 4.1, 4.6, and 5.9 for Zn, Cr, Cd, and Cu, respectively [22]. Another study done in South Korea revealed that a zeolite had Langmuir adsorption capacities (mg/g) of 6.5, 7.1, and 8.9 for Cu, Cd, and Pb, respectively [10]. The adsorption capacities of ICZ (Table 2) and 2.5 mg/g, respectively [24].…”
Section: Batch Equilibrium Adsorption Modellingmentioning
confidence: 99%
“…Some studies have shown that modification of zeolite surface by coating with iron (ICZ) can enhance the adsorption capacity of the zeolite for heavy metals [7][8][9][10][11]. In batch experiments, Han et al [8] found that an iron oxide-coated zeolite had greater adsorption capacity than zeolite for Cu.…”
Section: Introductionmentioning
confidence: 99%
“…They also stated that the average adsorption capacity calculated from the breakthrough curves followed the order of Pb > Cu > Cd. Similarly, Jeon et al [30] reported that the time taken for the effluent concentration of metals to reach the influent concentrations (Ce/Co =1) was longer for Cu than Cd when the metal solutions at pH 3 were passed through zeolite and iron oxide coated zeolite columns. During the entire experiment, no Pb was detected in the effluent of any of the columns.…”
Section: Mixed Metalsmentioning
confidence: 92%