2011
DOI: 10.2320/matertrans.l-m2011825
|View full text |Cite
|
Sign up to set email alerts
|

Application of High-Frequency Induction Heating Apparatus to Heat Treatment of 6061 Aluminum Alloy

Abstract: A high-frequency induction heating apparatus was used for the heat treatment of a commercial 6061 aluminum alloy bar with the objective of improving the mechanical properties and productivity. Heating states of the 6061 alloy bar were examined in terms of temperature distribution, heating rate, overheating and temperature fluctuation; moreover, the mechanical properties of the alloy after heat treatment were also investigated. The results of this study are as follows. When the 6061 alloy bar was rapidly heated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 10 publications
0
11
0
Order By: Relevance
“…In addition, induction techniques are sought for their fasthardening cycles, accurate heating pattern and cores that remain relatively cold and stable [2]. To achieve high temperature solution treatment, it is important to ensure rapid treatment, no overheating during the temperature transition [1][2]. Such characteristics minimize distortion and make heating outcomes extremely repeatable.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, induction techniques are sought for their fasthardening cycles, accurate heating pattern and cores that remain relatively cold and stable [2]. To achieve high temperature solution treatment, it is important to ensure rapid treatment, no overheating during the temperature transition [1][2]. Such characteristics minimize distortion and make heating outcomes extremely repeatable.…”
Section: Introductionmentioning
confidence: 99%
“…This type of hardening is becoming one of the preferred heating technologies, due to its advantages regarding efficiency, fast heating, safety, cleanness and accurate control, when compared with other classical heating techniques. In addition, induction techniques are sought for their fasthardening cycles, accurate heating pattern and cores that remain relatively cold and stable [2]. To achieve high temperature solution treatment, it is important to ensure rapid treatment, no overheating during the temperature transition [1][2].…”
Section: Introductionmentioning
confidence: 99%
“…The hardness increase at each position resulted from the extension of the holding time, while the quantity of hardness increase became lower for a holding time of 5 min or more. A previous report 13) on heat treatment with rapid heating pointed out that a sample must be heated to more than 713 K to increase the mechanical properties. The findings shown in Figs.…”
Section: Discussionmentioning
confidence: 99%
“…The frequency and power of the induction heating apparatus were 2 MHz and 10 kW, respectively. The surface of the sample was sprayed with a black coating to ensure precise temperature measurement using a radiation thermometer with a measurable temperature range of more than 523 K. Based on a previous study, 13) the emissivity value of the radiation thermometer was set to 0.78 to accurately measure the temperature. The radiation thermometer measured the temperature at the tip of the bar.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation