2021
DOI: 10.3390/app11072926
|View full text |Cite
|
Sign up to set email alerts
|

Application of High-Frequency Defrosting, Superheated Steam, and Quick-Freezing Treatments to Improve the Quality of Seafood Home Meal Replacement Products Consisting of the Adductor Muscle of Pen Shells and Common Squid Meat

Abstract: We developed a new seafood home meal replacement (HMR) product containing the adductor muscle of the pen shell (AMPS) and common squid meat (CSM) via high-frequency defrosting (HFD), superheated steam, and quick freezing. Test HMR products were produced by mixing defrosted and roasted AMPS, CSM, and sauce in ratios of 27.5, 27.5, and 45.0% (w/w), respectively, followed by quick freezing at −35 °C in a polypropylene plastic bowl covered with a plastic film. The chemical characteristics, nutritional quality, mic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 48 publications
4
8
0
Order By: Relevance
“…HFD was significantly different from the other thawing methods (p < 0.05). Similar results were reported by Negara et al [18] and Tirtawijaya et al [19]. The use of HFD successfully decreased the number of drip losses compared to conventional thawing methods.…”
Section: Drip Losssupporting
confidence: 88%
“…HFD was significantly different from the other thawing methods (p < 0.05). Similar results were reported by Negara et al [18] and Tirtawijaya et al [19]. The use of HFD successfully decreased the number of drip losses compared to conventional thawing methods.…”
Section: Drip Losssupporting
confidence: 88%
“…The drip loss after HFD was significantly lower (p < 0.05) than that of the other methods. This result is consistent with the results reported by Tirtawijaya et al [2], Negara et al [4], and Negara et al [5], who found that thawing via HFD resulted in a lower drip loss, as compared with conventional thawing methods.…”
Section: Drip Losssupporting
confidence: 92%
“…Moreover, amino acid analyzer (L-8900, Hitachi High-Tech Corp., Tokyo, Japan) was used to assess amino acid profiles. Fatty acid and amino acid profiles of the test HMR product were obtained according to a previous study [5].…”
Section: Nutritional Quality Analysismentioning
confidence: 99%