Application of fire-resistant steel to beam-to-column moment connections at elevated temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
3

Year Published

2012
2012
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(10 citation statements)
references
References 15 publications
0
7
0
3
Order By: Relevance
“…These steels have been tested by authors as Chung et al [26] in beams forming steel connections, proving their better fire performance. Their utility in steel columns was verified through a fire test carried out in Japan [21], where it was found that the fire resistance time of a column using FR steel was higher than that of a column of the same dimensions fabricated with a conventional steel.…”
Section: Introductionmentioning
confidence: 99%
“…These steels have been tested by authors as Chung et al [26] in beams forming steel connections, proving their better fire performance. Their utility in steel columns was verified through a fire test carried out in Japan [21], where it was found that the fire resistance time of a column using FR steel was higher than that of a column of the same dimensions fabricated with a conventional steel.…”
Section: Introductionmentioning
confidence: 99%
“…Full details of these are not included here, but the interested reader could refer to Yu et al (2009Yu et al ( , 2011 for information on fire testing of steel bolted connections, Ding and Wang (2007) for information on fire testing of connections between steel beams and concrete-filled hollow structural sections, Chung et al (2010) for tests on steel beam-to-column moment resisting connections, and Yuan et al (2011) for information on fire testing of connections involving steelconcrete composite beams, including the influence of the concrete deck slab. The important conclusion from this body of work is simply that, as already noted, the performance of structural connections in fire is of fundamental importance to the response of real structures in real fires, and that the relevant failure modes are impossible to observe or predict using standard furnace testing of isolated structural elements.…”
Section: Testing On Steel Connections In Firementioning
confidence: 99%
“…이는 주로 일본과 유럽 중심으로 이루어졌으며, 대표적인 연구사례로써는 Sakumodo 등 (11)(12)(13) 와 Sha 등 (14,15) 의 연구가 있다. 최근에는 내화강재를 대상으로 보부재와 기둥부재의 고온 시의 내력평가가 Yang, Chung을 중심으 로 진행되고 있다 (16)(17)(18) . (19) .…”
Section: 강구조 건축물을 대상으로 내화공학설계를 수행하기 위 해서는 고온 시의 내력 감소 및 이차 응력 평가를 위하여unclassified