Organic Indoor Air Pollutants 2009
DOI: 10.1002/9783527628889.ch3
|View full text |Cite
|
Sign up to set email alerts
|

Application of Diffusive Samplers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Passive sampling, whose theoretical fundamentals were described in detail and summarized by Crump,( 185 ) is enjoying increasing popularity in indoor air testing, since it can be employed without causing any nuisance to room users. Different types of formaldehyde passive samplers have been employed.…”
Section: Sampling and Analysis Of Formaldehydementioning
confidence: 99%
See 2 more Smart Citations
“…Passive sampling, whose theoretical fundamentals were described in detail and summarized by Crump,( 185 ) is enjoying increasing popularity in indoor air testing, since it can be employed without causing any nuisance to room users. Different types of formaldehyde passive samplers have been employed.…”
Section: Sampling and Analysis Of Formaldehydementioning
confidence: 99%
“…In the case of active sampling, air is passed through a sampling device using a pump and the air volume is accurately determined. A passive sampler is a device which is capable of taking air samples at a rate controlled by diffusion through a static layer or permeation through a membrane . The flow of pollutants into the passive sampler is proportional to the difference of concentrations in the ambient air ( C air ) and on the surface of the passive sampler ( C A ), as shown in eq .…”
Section: Sampling and Analysis Of Formaldehydementioning
confidence: 99%
See 1 more Smart Citation
“…Diffusive samplers are small and convenient tubes and badges that can be placed in a building by an investigator, or sent to the occupants of buildings under investigation [17]. The diffusive sampler provides a measure of the mean concentration over periods of days or weeks in the building under conditions of normal occupation.…”
Section: Requirements For Iaqmentioning
confidence: 99%
“…It allows the sampling of most VOCs but can also sample SVOCs and particles [ 17 , 18 ]. In some studies, passive sampling has been used for VVOCs but has shown an underestimation of their concentration [ 19 ]. Active sampling is preferable for sampling VVOCs [ 20 ].…”
Section: Introductionmentioning
confidence: 99%