2021
DOI: 10.1016/j.jchromb.2021.122584
|View full text |Cite
|
Sign up to set email alerts
|

Application of comprehensive 2D chromatography in the anti-doping field: Sample identification and quantification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 51 publications
(63 reference statements)
0
6
0
Order By: Relevance
“…The DBS method for detecting anabolic steroids is not currently popular, but it has many advantages and is expected to be widely used in routine doping analyses. Hand et al ( 36 ) considered that WADA-accredited laboratories seemed to pay attention to the improvement of MS, but neglected the improvement of chromatographic technology, especially the application of 2D chromatography. Anti-doping analysis requires extreme accuracy and precision, and although chromatography combined with MS analysis is effective in achieving good selectivity and specificity, there are still some limitations.…”
Section: Common Doping Tests Used For Food Of Animal Originmentioning
confidence: 99%
“…The DBS method for detecting anabolic steroids is not currently popular, but it has many advantages and is expected to be widely used in routine doping analyses. Hand et al ( 36 ) considered that WADA-accredited laboratories seemed to pay attention to the improvement of MS, but neglected the improvement of chromatographic technology, especially the application of 2D chromatography. Anti-doping analysis requires extreme accuracy and precision, and although chromatography combined with MS analysis is effective in achieving good selectivity and specificity, there are still some limitations.…”
Section: Common Doping Tests Used For Food Of Animal Originmentioning
confidence: 99%
“…and lm thickness of the 2 D column. 45 A deactivated universal press-t connector (Agilent Technologies Inc.) was used to connect the two columns through the LMCS, with the trap temperature set at different constant temperatures, which were 10, 80, 150, and 220 C. The P M of 8 or 12 s was applied. Helium was used as a carrier gas with a constant ow rate of 1.4 mL min À1 .…”
Section: Instrumentationmentioning
confidence: 99%
“…LC‐MS/MS and GC‐MS/MS, even though effective, lack targeted analysis and the inability to detect new or modified compounds due to selective monitoring. Note that, 2D chromatography overcomes these pitfalls by increasing the resolution power and peak capacity for enabling the identification of unknown compounds in complex matrices; thus, gaining importance in the field of anti‐doping [30].…”
Section: Ms and Metabolomic Approach Used In Anti‐dopingmentioning
confidence: 99%