2003
DOI: 10.1021/ac020788z
|View full text |Cite
|
Sign up to set email alerts
|

Application of Avidin−Biotin Technology and Adsorptive Transfer Stripping Square-Wave Voltammetry for Detection of DNA Hybridization and Avidin in Transgenic Avidin Maize

Abstract: The proteins streptavidin and avidin were electrochemically detected in solution by adsorptive transfer stripping square wave voltammetry (AdTS SWV) at a carbon paste electrode (CPE). AdTS SWV was used to quantify biotinylated oligonucleotides, DNA hybridizations, and avidin in extracts of transgenic avidin maize. The detection limits of denatured and native streptavidin were 6 pM and 120 nM, respectively. The results demonstrated that streptavidin/avidin AdTS SWV is a sensitive and specific method for quantif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
55
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 110 publications
(55 citation statements)
references
References 36 publications
(74 reference statements)
0
55
0
Order By: Relevance
“…The filtrate was centrifuged at 14 500 g for 15 min at 4°C. The pH of the supernatant was adjusted to pH 10.5 and then was centrifuged at 14 000 g for 30 min (Eppendorf 5402) in 4°C (Hood et al 1997, Masarik et al 2003). The resulting supernatant was then used to prepare the modified CPE.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The filtrate was centrifuged at 14 500 g for 15 min at 4°C. The pH of the supernatant was adjusted to pH 10.5 and then was centrifuged at 14 000 g for 30 min (Eppendorf 5402) in 4°C (Hood et al 1997, Masarik et al 2003). The resulting supernatant was then used to prepare the modified CPE.…”
Section: Methodsmentioning
confidence: 99%
“…It is known that the carbon paste electrode (CPE) is suitable for biosensors construction (Wang 1985, Wang et al 1997, Wang et al 1999, Wang et al 2000. Moreover, the carbon paste electrode can be modified by addition of various compounds in order to increase the sensitivity, selectivity and rapidness of the determination (Wang and Lin 1988, Kubiak and Wang 1989, Masarik et al 2003, Kizek et al 2005). In our work we used the carbon electrodes (CPE and modified CPE) coupled with square-wave voltammetry to measure nanogram amount of avidin.…”
mentioning
confidence: 99%
“…Electrochemical method for measurement of recombinant protein levels ( Fig. 8) using transgenic avidin maize as a model GMO, was reported by Masarik et al [158]. A disposable genosensor for GMO has been reported by Meric et al through detecting the nearly ubiquitous genetic element of transgenic organisms -NOS-terminator [159].…”
Section: Gmo Contentmentioning
confidence: 99%
“…(14), aprotinin (7.6); 2) native streptavidin; 3) thermally denatured streptavidin (99 8C, 30 min); 4) 10 mg of avidin-positive maize seed extract; 5) 10 mg of avidin-negative maize seed extract (negative control); 6) 10 mg of avidin-negative corn low-grade flour extract; 7) 10 mg of avidin-negative corn grout extract; 8) 10 mg of avidin-negative corn grits extract, and 9) 10 mg of avidin-negative corn farina extract. (from [158] with permission).…”
Section: Acknowledgementsmentioning
confidence: 99%
“…Under this scope, a series of experiments were performed using concentration levels for STR and bio-ODN of 2000 mg mL À1 and 100 mg mL À1 , respectively. In the case of STR modified CNT-PGEs, the voltammogram showed a broad peak at potential of þ 0.798 V (shown in Figure 1Ab), which is attributed to tryptophan and tyrosine residues in STR that can be oxidized electrochemically at carbon electrodes [29,30]. The biotinylated DNA attachment onto STR coated surface caused a decrease at the signal of STR ( Figure 1Ac) as a result of the specific and strong binding between STR and biotin.…”
mentioning
confidence: 98%