Application of Au@Pt Nanozyme as Enhancing Label for the Sensitive Lateral Flow Immunoassay of Okadaic Acid

Abstract: In this study, a lateral flow immunoassay (LFIA) was developed to detect okadaic acid (OA) belonging to the diarrheic shellfish poisoning group of aquatic toxins. Newly obtained anti-OA monoclonal antibodies and bimetallic core@shell Au@Pt nanoparticles were used in the indirect format of the LFIA. Peroxidase-mimicking nanozyme properties of Au@Pt enabled using them to enhance band coloration on the test strips and, consequently, for increasing the LFIA sensitivity. The instrumental limit of detection (LOD), t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 38 publications
0
11
0
Order By: Relevance
“…In general, LODs of OA are lower in ELISAs, approximately reaching picogram values [ 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ]. In ICAs [ 44 , 45 , 46 , 47 , 48 , 49 ], including multiparametric ones [ 18 , 20 , 50 ], the sensitivity of the determination is somewhat worse (up to the nanogram concentration range), and improvements in this method were achieved with amplification approaches aimed at increasing analytical signal [ 19 , 51 ]. The duration of the analysis in the case of ICA is 10–40 min.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In general, LODs of OA are lower in ELISAs, approximately reaching picogram values [ 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ]. In ICAs [ 44 , 45 , 46 , 47 , 48 , 49 ], including multiparametric ones [ 18 , 20 , 50 ], the sensitivity of the determination is somewhat worse (up to the nanogram concentration range), and improvements in this method were achieved with amplification approaches aimed at increasing analytical signal [ 19 , 51 ]. The duration of the analysis in the case of ICA is 10–40 min.…”
Section: Resultsmentioning
confidence: 99%
“…Because there is no need for the separation of bound and unbound immunoreagents, the duration of the FPIA is only 5 min, which is even shorter than all the rapid ICA-based test systems considered. In addition, the FPIA does not require sample preparation of the liquid matrix, unlike the ICA of the same matrices [ 19 , 45 ]. The preparation for the analysis requires only the synthesis of a tracer and does not include any preliminary stages such as the sorption of coating antigens (similar to the microplate-based ELISA) or the application of the reagents on membrane carriers (similar to the ICA).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The effects of hairpin action time (15,30,45, and 60 min) on the hairpin reaction were detected. The results showed no difference among hairpin action times, suggesting that the hairpin reaction was rapid (Figure 5A,B).…”
Section: Effects Of Hairpin Concentration Action Time and Temperature...mentioning
confidence: 99%
“…Over the past two decades, nanomaterials with enzyme-like characteristics, termed nanozyme, have attracted great attention because of their easy preparation, good stability in harsh conditions, and low cost. Up to now, a variety of nanomaterials have been discovered with enzyme-mimicking activity, such as transition metal oxide-based nanomaterials [ 14 , 15 , 16 , 17 ], noble metal- or metal-based nanostructures [ 18 , 19 , 20 ], carbon-based nanomaterials [ 21 , 22 , 23 ], and metal–organic framework-based nanostructures (MOFs) [ 24 , 25 , 26 ]. Although some progress has been made in this field, conventional nanozymes still face great challenges such as insufficient enzyme-like activity and low selectivity compared with natural enzymes.…”
Section: Introductionmentioning
confidence: 99%