Application of an electrochemical LAMP-based assay for screening of HPV16/HPV18 infection in cervical samples

Abstract: Clinical evaluation of rapid, simple and inexpensive electrochemical assay using LAMP amplification for detection of two most oncogenic human papillomavirus types, HPV16 and HPV18.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 34 publications
0
8
0
2
Order By: Relevance
“…In the next attempt, 61 cervical samples for both genotypes were screened and validated with real-time PCR and commercial HPV tests such as INNO-LiPA and COBAS. The system had 90% accuracy [ 80 ]. Recently, Ramírez-Chavarría et al [ 81 ] proposed a LAMP-based low-cost electrochemical sensor for specific detection of a SARS-CoV-2 gene sequence, in which RT-LAMP is performed on a disposable test strip consisting of a screen-printed electrode.…”
Section: Lamp Detection Methodsmentioning
confidence: 99%
“…In the next attempt, 61 cervical samples for both genotypes were screened and validated with real-time PCR and commercial HPV tests such as INNO-LiPA and COBAS. The system had 90% accuracy [ 80 ]. Recently, Ramírez-Chavarría et al [ 81 ] proposed a LAMP-based low-cost electrochemical sensor for specific detection of a SARS-CoV-2 gene sequence, in which RT-LAMP is performed on a disposable test strip consisting of a screen-printed electrode.…”
Section: Lamp Detection Methodsmentioning
confidence: 99%
“…Our team has published several research articles reporting fast and simple LAMP‐based assays combined with electrochemical detection (EC‐LAMP), targeting HPV16/18 genotypes in both cervical cell lines and cervical smears from women with precancerous lesions (Figure 1). 79–82 After development and optimization of the assay, 80 the EC‐LAMP was applied into a cohort of 61 clinical samples to evaluate its performance and compared it with PCR‐based methods and with INNO‐LiPA genotyping assay 81 . Good specificity and negative and positive predictive values were reached, all over 90%.…”
Section: Isothermal Amplification Techniques As Rapid Alternatives To...mentioning
confidence: 99%
“…It requires 4-6 primers which makes the reaction highly sequence-specific and generates products of variable lengths, ranging from hundreds to few thousand bp. LAMP is widely used for pathogen analysis not only in a fluorescent or colorimetric format [117][118][119][120], but also in electrochemical assays to detect viruses, such as human papillomavirus (HPV) [121][122][123][124] and hepatitis virus B [125], and bacteria (E. coli, Salmonella, etc.) [126,127].…”
Section: Iat-based Ec Biosensorsmentioning
confidence: 99%
“…Indeed, the access to human clinical samples does not represent an insurmountable obstacle, as demonstrated by EC works that successfully employed their assays into patient samples with satisfactory results [69,70,73,75,78,141]. It would be highly beneficial if some EC strategy is applied to a larger cohort of patients (tens or even hundreds) and compared with a standard method of detection with rigorous statistics; this feature of EC assays is currently in its infancy [99,124,142], but would increase an impact of electrochemistry in clinical diagnostics.…”
Section: Outlook and Conclusionmentioning