2021
DOI: 10.1049/gtd2.12313
|View full text |Cite
|
Sign up to set email alerts
|

Application of adaptive chirp mode decomposition on parameter identification of sub/super‐synchronous oscillation signals

Abstract: Identifying the parameters of sub/super‐synchronous oscillation (SubSO/SupSO) signals is challenging, because (1) the mode numbers of the oscillation signals are unknown, and (2) the oscillation signals are non‐stationary and noisy. The non‐stationary components need to be accurately identified in order to efficiently suppress SubSO/SupSO. Here, an adaptive chirp mode decomposition (ACMD) method joining a synchroextracting transform (SET) is exploited. First, for detecting the initial instantaneous frequencies… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 23 publications
(37 reference statements)
0
1
0
Order By: Relevance
“…Stability analysis approaches for a multi-inverter-fed power system should adapt to the replacement of synchronous generators in traditional power systems by clean, inverter-based resources [1]. Unstable problems, such as those induced by the coupling between grids and grid-connected inverters (GCIs), have been analysed [2][3][4]. The internal parameters, control methods, structure, and other information pertaining to gridconnected inverters at engineering sites are unknown owing to the technical confidentiality restrictions imposed by the equipment supplier.…”
Section: Introductionmentioning
confidence: 99%
“…Stability analysis approaches for a multi-inverter-fed power system should adapt to the replacement of synchronous generators in traditional power systems by clean, inverter-based resources [1]. Unstable problems, such as those induced by the coupling between grids and grid-connected inverters (GCIs), have been analysed [2][3][4]. The internal parameters, control methods, structure, and other information pertaining to gridconnected inverters at engineering sites are unknown owing to the technical confidentiality restrictions imposed by the equipment supplier.…”
Section: Introductionmentioning
confidence: 99%
“…[5] But the least square method belongs to the linear estimation, the default system is linear relationship, use has certain limitations. [6] In reference [7] , a parameter identification method of photovoltaic array based on the hybrid algorithm of artificial fish swarm and leapfrog was proposed. Referrnce [8] proposes a parameter identification strategy based on gray wolf algorithm.…”
Section: Introductionmentioning
confidence: 99%
“…Stability analysis approaches for a multi-inverterfed power system should adapt to the replacement of synchronous generators in traditional power systems by clean, inverter-based resources [1]. Unstable accidents, such as those induced by the coupling between grids and grid-connected inverters (GCIs), have been reported [2][3][4]. The internal parameters, control methods, structure, and other information pertaining to grid-connected inverters at engineering sites are unknown owing to the technical confidentiality restrictions imposed by the equipment supplier.…”
Section: Introductionmentioning
confidence: 99%