2023
DOI: 10.1016/j.ica.2022.121276
|View full text |Cite
|
Sign up to set email alerts
|

Application of a Rhodamine-chromone Schiff base probe for the sensing of Fe3+, Al3+, Cr3+ at low concentration and exploration of the anticancer activity and bio-imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 43 publications
0
4
0
Order By: Relevance
“…Maity et al reported a chromone linked rhodamine unit ( 53 ) (Scheme 8) via an ethyl linkage for sensing Fe 3+ , Al 3+ and Cr 3+ in methanol–water (99 : 1, v/v; HEPES buffer, pH, 7.2). 72 A significant increase in fluorescence intensity of the probe was observed at 583 in the presence of each of the trivalent cations which was attributed to the opening of the spirolactam ring followed by coordination with amide O and imine N atoms. The LOD values were calculated to be 0.0051 ppm for Fe 3+ , 0.0029 ppm for Al 3+ and 0.0052 ppm for Cr 3+ .…”
Section: Introductionmentioning
confidence: 95%
“…Maity et al reported a chromone linked rhodamine unit ( 53 ) (Scheme 8) via an ethyl linkage for sensing Fe 3+ , Al 3+ and Cr 3+ in methanol–water (99 : 1, v/v; HEPES buffer, pH, 7.2). 72 A significant increase in fluorescence intensity of the probe was observed at 583 in the presence of each of the trivalent cations which was attributed to the opening of the spirolactam ring followed by coordination with amide O and imine N atoms. The LOD values were calculated to be 0.0051 ppm for Fe 3+ , 0.0029 ppm for Al 3+ and 0.0052 ppm for Cr 3+ .…”
Section: Introductionmentioning
confidence: 95%
“…The chemosensor has a detection limit of 2.12 × 10 −8 M and has been successfully prepared as an assay test paper for convenient usage. A novel fluorescent probe, RFC, was synthesized by combining rhodamine and chromone through carbon-nitrogen conjugation for the purpose of detecting Cr 3+ [65]. The fluorescent probe is effective in the MeOH/H 2 O (99:1, v/v) system and has a detection limit of 0.0052 ppm.…”
Section: Fluorescent Probes To Detect Cr 3+mentioning
confidence: 99%
“…Further, they were assessed for anticancer activity and were found to be effective against MCF-7 cells, glucocorticoid, and progesterone receptors. 45 Barve et al 46 synthesized copper ion conjugated chromone Schiff base complexes (IV) these compounds demonstrated their effectiveness as inhibitors against BT20, PC-3, as well as both COLO 357 and BxPC-3 cancer cell lines. Thus, it can be affirmatively suggested that the metal complexes exhibit better biological activity.…”
Section: Introductionmentioning
confidence: 99%