Application of a New Validated HPLC-PDA Method for Simultaneous Determination of Curcumin and Melatonin in Hyaluronic Acid-Coated Nanoemulsions

Abstract: In this study, a high-performance liquid chromatography with photodiode array detector (HPLC-PDA) method was developed and validated to simultaneously determine curcumin (CUR) and melatonin (MEL) in hyaluronic acid-coated nanoemulsions, a novel targetable delivery system to CD44 receptors overexpressed in many types of tumors. Chromatographic analyses were performed in reversed phase mode using a mobile phase consisting of acetonitrile, methanol and 0.1% formic acid (35:15:50, v/v/v) at a flow rate of 1 mL min… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 40 publications
0
3
0
Order By: Relevance
“…3 ), confirms that the excipients in the nanoparticles did not interfere in the CUR peak obtained for CUR loaded nanoparticles, evidencing the specificity of the method. [ 53 ] In a previous study, the linearity concentration range for estimation of CUR using spectrofluorimetric analysis was 50-500ng/mL with %accuracy of 80, 100 and 120% showed percent recoveries ranging from 96.33 to 100.75%. The precision results from the literature showed an RSD of less than 8% which was more than the present developed method of < 5% [ 36 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…3 ), confirms that the excipients in the nanoparticles did not interfere in the CUR peak obtained for CUR loaded nanoparticles, evidencing the specificity of the method. [ 53 ] In a previous study, the linearity concentration range for estimation of CUR using spectrofluorimetric analysis was 50-500ng/mL with %accuracy of 80, 100 and 120% showed percent recoveries ranging from 96.33 to 100.75%. The precision results from the literature showed an RSD of less than 8% which was more than the present developed method of < 5% [ 36 ].…”
Section: Resultsmentioning
confidence: 99%
“…The percentage accuracy ranged from 97.06 to 97.88% with an RSD of less than 4% shown in Table 2 , indicating a low variability and close agreement between the experimental and theoretical concentration values. [ 53 ] LOD and LOQ values for the CUR were found to be 25 ng/mL and 50 ng/mL.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation