2012
DOI: 10.1016/j.conbuildmat.2011.06.029
|View full text |Cite
|
Sign up to set email alerts
|

Application of a LTCC sensor for measuring moisture content of building materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 19 publications
0
14
0
1
Order By: Relevance
“…Working principle of the presented sensors is based on the capacitance change of sensor's capacitive part when it is exposed to different moisture concentration (similar principle was already reported in our earlier papers [24,25]). Namely, dielectric constant of water is greater than for the air, thus capacitance increases with increasing the water content in tested building materials.…”
Section: Working Principlesmentioning
confidence: 63%
“…Working principle of the presented sensors is based on the capacitance change of sensor's capacitive part when it is exposed to different moisture concentration (similar principle was already reported in our earlier papers [24,25]). Namely, dielectric constant of water is greater than for the air, thus capacitance increases with increasing the water content in tested building materials.…”
Section: Working Principlesmentioning
confidence: 63%
“…Through this window the sensor is exposed to moisture, which will then cause change of its dielectric constant and total capacitance and consequently the resonant frequency of the LC sensor. The sensor exhibits from 0% to 70% wide detection range of water absorption with high linearity and fast response [1].…”
Section: B Electrical Measurementsmentioning
confidence: 99%
“…Перспективным направлением в плане повышения производительности подобных исследований является разработка импульсных методов неразрушающего контроля (НК), характеризующихся малой длительностью процессов измерений и широко использующихся для определения теплофизических характеристик [7,8]. Задача достижения сопоставимой производительности при разработке аналогичных методов НК для измерения характеристик массопереноса осложнена необходимостью проведения длительной предварительной операции градуировки применяемых датчиков концентрации диффузанта по каждой системе композит−диффундирующее вещество [4][5][6]9,10]. А измерение локальной концентрации диффундирующих веществ, лежащее в основе реализации методов НК, представляет собой достаточно сложную задачу по сравнению с измерением локальных значений температуры [5,6,11].…”
unclassified