2007
DOI: 10.1016/j.ijthermalsci.2006.02.006
|View full text |Cite
|
Sign up to set email alerts
|

Application of a heat pipe heat exchanger to dehumidification enhancement in a HVAC system for tropical climates—a baseline performance characteristics study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0
4

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 76 publications
(49 citation statements)
references
References 4 publications
0
45
0
4
Order By: Relevance
“…To this end, this investigation has been carried out and the aims of this paper are two-fold; investigation into how the enthalpy change across the chilled water coil (CWC) was influenced by each of three key inlet parameters, namely, inlet dry-bulb temperature (DBT), inlet relative humidity (RH) and air mass flux rate. These experimental results, in comparison with those already obtained (Yau, 2006), would also allow an examination of how the reheat recovery with the 8-row HPHX installed was influenced by the same key inlet parameters. Note that the better energy performance could be achieved if the enthalpy change across the active cooling path in the HVAC system is enhanced by installation of a HPHX in the system.…”
Section: Introductionmentioning
confidence: 59%
See 2 more Smart Citations
“…To this end, this investigation has been carried out and the aims of this paper are two-fold; investigation into how the enthalpy change across the chilled water coil (CWC) was influenced by each of three key inlet parameters, namely, inlet dry-bulb temperature (DBT), inlet relative humidity (RH) and air mass flux rate. These experimental results, in comparison with those already obtained (Yau, 2006), would also allow an examination of how the reheat recovery with the 8-row HPHX installed was influenced by the same key inlet parameters. Note that the better energy performance could be achieved if the enthalpy change across the active cooling path in the HVAC system is enhanced by installation of a HPHX in the system.…”
Section: Introductionmentioning
confidence: 59%
“…The same experimental set-up and procedures described by Yau (2006) were used for the current investigation, with the exception that in the current investigation, the gate valve in the thermostated chilled water circulator system was used to control the flow rate of the chilled water (i.e. control the cooling capacity of the CWC) for comparison purposes.…”
Section: Experimental Set-up and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…2. Investigation of the effectiveness coefficient for calculating the performance of the heat pipe heat exchanger itself rather than the whole HVAC system (Yau 2007b). …”
Section: Overview Of Relevant Theorymentioning
confidence: 99%
“…In another study by Srimuang et al [7] the application of heat pipe heat exchangers for heat recovery focused on the energy savings and provideing additional information for the design of heat pipe heat exchangers with optimum conditions in heat recovery systems was reviewed. Yau [8][9][10][11][12] conducted a series of experimental studies on the use of HP technology for tropical climates and gave a review of research on the application of heat pipe heat exchangers in air conditioning systems.…”
Section: Introductionmentioning
confidence: 99%