2011
DOI: 10.1002/elan.201100242
|View full text |Cite
|
Sign up to set email alerts
|

Application of a Carbon‐Paste Electrode Modified with 2,7‐Bis(ferrocenyl ethyl)fluoren‐9‐one and Carbon Nanotubes for Voltammetric Determination of Levodopa in the Presence of Uric Acid and Folic Acid

Abstract: A carbon-paste electrode modified with 2,7-bis(ferrocenyl ethyl)fluoren-9-one and carbon nanotubes was used for the sensitive voltammetric determination of levodopa (LD). The electrochemical response characteristics of the modified electrode toward LD, uric acid (UA) and folic acid (FA) were investigated. The results showed an efficient catalytic activity of the electrode for the electrooxidation of LD, which leads to lowering its overpotential by more than 320 mV. The modified electrode exhibits an efficient … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
33
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 105 publications
(35 citation statements)
references
References 42 publications
1
33
0
Order By: Relevance
“…The anodic peak potential of MTX is shifted negatively with the increase of the pH value, indicating reactions accompanied by proton transfer. The slopes of 63.6 mV/pH for MTX oxidation is nearby to the theoretical value of 59 mV/pH and pointed out toward two protons and two electrons involved in the oxidation process [28][29][30]. The detection limit (LOD) was estimated by applying the standard formula of LOD = 3sb/m [31], where m is the slope of the calibration curve and sb is the standard deviation of the peak currents of the blank solution (five replicates).…”
Section: Relationship Between Ph Peak Potential and Peak Current Valuessupporting
confidence: 67%
“…The anodic peak potential of MTX is shifted negatively with the increase of the pH value, indicating reactions accompanied by proton transfer. The slopes of 63.6 mV/pH for MTX oxidation is nearby to the theoretical value of 59 mV/pH and pointed out toward two protons and two electrons involved in the oxidation process [28][29][30]. The detection limit (LOD) was estimated by applying the standard formula of LOD = 3sb/m [31], where m is the slope of the calibration curve and sb is the standard deviation of the peak currents of the blank solution (five replicates).…”
Section: Relationship Between Ph Peak Potential and Peak Current Valuessupporting
confidence: 67%
“…Therefore, its determination in physiological fluids is necessary in the diagnosis and treatment of diseases such as gout, hyperuricemia, heavy hepatitis, and Lesch-Nyhan syndrome [11]. UA is also a marker for renal failure as well as toxicity.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, some references may be mentioned: for instance, the determination of captopril, thioguanine and levodopa (Beitollahi et al, 2014(Beitollahi et al, , 2011a(Beitollahi et al, , 2011b, L-cysteine with ascorbic acid, (Raoof et al, 2007(Raoof et al, , 2006a(Raoof et al, , 2006b, hydroquinone derivatives (Taleat et al, 2008) and simultaneous determinations of carbidapa (Tajik et al, 2013).…”
Section: Introductionmentioning
confidence: 99%