Applicability of two-dimensional thermoluminescence slab dosimeter based on Al 2 O 3 :Cr for the quality assurance of robotic radiosurgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…2.4.2. (8) For the quality control of a radiation therapy system using the dose distribution, it is important to evaluate the invariance of the beam shape. For this evaluation, 80% of the beam area closest to the center is recommended.…”
Section: Absorbed Dose Distribution Measurement Using Tlsdmentioning
confidence: 99%
See 1 more Smart Citation
“…2.4.2. (8) For the quality control of a radiation therapy system using the dose distribution, it is important to evaluate the invariance of the beam shape. For this evaluation, 80% of the beam area closest to the center is recommended.…”
Section: Absorbed Dose Distribution Measurement Using Tlsdmentioning
confidence: 99%
“…It has been shown that the dose distribution can be obtained using the absorbed dose correction factor. (8) If a sufficiently high accuracy in postal dosimetry measurement using a TLSD can be achieved, TLSDs can be used by third parties to evaluate dose distributions.…”
Section: Introductionmentioning
confidence: 99%
“…Some results were not as promising as others-several powdered doped Al 2 O 3 samples produced by solution combustion method were characterized for TL and OSL properties [6]; however, they did not demonstrate attractive dosimeter properties. At the same time, Japanese researchers have found that doping with Cr enhances sensitivity and the fading characteristics of alumina, demonstrated in X-ray imaging, which makes this material suitable for two-dimensional TL slab dosimeters for robotic radiosurgery systems [7]. As shown in [8] doping of nanopowdered Al 2 O 3 with chromium makes it sensitive to higher γ-ray doses (100 Gy-20 kGy without saturation).…”
Section: Introductionmentioning
confidence: 98%
“…A previous study suggested that 2D Al 2 O 3 :Cr TLDs have high applicability for the quality assurance of robotic radiosurgery. (17) However, Al 2 O 3 :Cr TLDs lack tissue equivalence. Also, multienergy X-ray beams are used in radiotherapy, while only 6 MV X-ray beams are used in robotic radiosurgery.…”
Section: Introductionmentioning
confidence: 99%