1976
DOI: 10.1007/bf01120166
|View full text |Cite
|
Sign up to set email alerts
|

Applicability of the method of magnetosonic heating for thermonuclear parameters of a plasma in a tokamak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
4
0

Year Published

1987
1987
2007
2007

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
1
4
0
Order By: Relevance
“…Here, the brackets < > denote integrating over the fluctuation spectrum. According to evaluations of [31a], an expression identical with (23) gives rather good agreement with observations of energy losses in several tokamaks. But more recent considerations based on the study of some concrete instabilities (for example, trapped particle instability dealt with in [ 16a]) result in a decrease of the diffusion coefficient and fail to explain the experimental data.…”
Section: Electrostatic Fluctuationssupporting
confidence: 71%
See 2 more Smart Citations
“…Here, the brackets < > denote integrating over the fluctuation spectrum. According to evaluations of [31a], an expression identical with (23) gives rather good agreement with observations of energy losses in several tokamaks. But more recent considerations based on the study of some concrete instabilities (for example, trapped particle instability dealt with in [ 16a]) result in a decrease of the diffusion coefficient and fail to explain the experimental data.…”
Section: Electrostatic Fluctuationssupporting
confidence: 71%
“…But more recent considerations based on the study of some concrete instabilities (for example, trapped particle instability dealt with in [ 16a]) result in a decrease of the diffusion coefficient and fail to explain the experimental data. In our opinion, in solving this question, one should take into account a full drift turbulence spectrum, S(k r , k x , k h o ) , since the account of fairly small k,, ~ 1/qR can lead to a decrease of r c in formula (23).…”
Section: Electrostatic Fluctuationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Injected beam ions have been accelerated by ion cyclotron heating (ICH) at cyclotron harmonics in many tokamaks [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17]. Most measurements of acceleration by ICH have employed neutral particle analysis [18,19], although fusion reaction measurements of neutrons and charged fusion products are also common [19,20]. Differences between the perpendicular and equilibrium stored energy are used to measure the anisotropic fast-ion energy [21].…”
Section: Introductionmentioning
confidence: 99%
“…However, a Balmer-alpha diagnostic can only make a species mix measurement of neutral hydrogen, which is generally concentrated at the plasma boundary; interior activity goes undetected. Another method detects neutral particles that undergo charge exchange reactions in the plasma and escape to a mass-resolving neutralparticle analyser [3,4]. Although neutrals are rare in the core of a hot plasma, injection of a modulated neutral beam can enhance the signal that originates in the core [5].…”
Section: Introductionmentioning
confidence: 99%