2008
DOI: 10.5194/acp-8-4049-2008
|View full text |Cite
|
Sign up to set email alerts
|

Applicability of condensation particle counters to measure atmospheric clusters

Abstract: Abstract. This study presents an evaluation of a pulse height condensation particle counter (PH-CPC) and an expansion condensation particle counter (E-CPC) in terms of measuring ambient and laboratory-generated molecular and ion clusters. Ambient molecular cluster concentrations were measured with both instruments as they were deployed in conjunction with an ion spectrometer and other aerosol instruments in Hyytiälä, Finland at the SMEAR II station between 1 March and 30 June 2007. The observed cluster concent… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
46
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
4
3
1

Relationship

3
5

Authors

Journals

citations
Cited by 74 publications
(49 citation statements)
references
References 29 publications
3
46
0
Order By: Relevance
“…These instruments include the Neutral cluster and Air Ion Spectrometer (NAIS, Kulmala et al, 2007a), Ion-Differential Mobility Particle Sizer , Condensation Particle Counter Battery , various other CPC techniques (Sipilä et al, 2008;Vanhanen et al, 2011), and the Atmospheric Pressure Interface Time of Flight Mass Spectrometer (API-ToF-MS, Junninen et al, 2010;Ehn et al, 2010).…”
Section: E1 In-situ Formation (Nucleation) Of Aerosolsmentioning
confidence: 99%
“…These instruments include the Neutral cluster and Air Ion Spectrometer (NAIS, Kulmala et al, 2007a), Ion-Differential Mobility Particle Sizer , Condensation Particle Counter Battery , various other CPC techniques (Sipilä et al, 2008;Vanhanen et al, 2011), and the Atmospheric Pressure Interface Time of Flight Mass Spectrometer (API-ToF-MS, Junninen et al, 2010;Ehn et al, 2010).…”
Section: E1 In-situ Formation (Nucleation) Of Aerosolsmentioning
confidence: 99%
“…The PHA-UCPC comprises a butanolbased UCPC (TSI 3025A) with modified white light optics and a multi-channel analyser (Dick et al, 2000). Pulse height analysis technique allows distinguishing between homogeneously nucleated droplets and droplets formed by heterogeneous nucleation on particles with sizes below 2 nm in mobility diameter (Sipilä et al, 2008(Sipilä et al, , 2009. Therefore, very high butanol super-saturations can be used to maximize the detection efficiency at sub-3 nm size range.…”
Section: High Sensitivity Particle Measurementsmentioning
confidence: 99%
“…The temperature difference between the CPC condenser and saturator was increased until homogenous nucleation of condensing liquid, n-butanol, occurred. The pulse-height analysis method allows distinction between activation of nano-CN and homogenous nucleation (Sipilä et al, 2008). Every other measurement was made through a diffusion tube, which enabled subtraction of the pulses from homogenous nucleation.…”
Section: Instruments and Measurementsmentioning
confidence: 99%
“…Ions were filtered away by applying a voltage to an ion trap. The PH-CPC is capable of detecting particles down to ∼ 1.3 nm in mobility diameter with a detection efficiency of a few percent (Sipilä et al, 2008), but the exact size scale and detection efficiency depends on particle composition, charge and background aerosol concentration (O'Dowd, 2004;Sipilä et al, 2009). The data inversion to resolve particle size distribution between 1.3 and 5 nm is based on experimental calibrations with positive silver and Am241-charger generated ions.…”
Section: Instruments and Measurementsmentioning
confidence: 99%
See 1 more Smart Citation