2023
DOI: 10.1038/s41598-023-28800-z
|View full text |Cite
|
Sign up to set email alerts
|

Apparent diameter and cell density of yeast strains with different ploidy

Abstract: Optical density at 600 nm (OD600) measurements are routinely and quickly taken to estimate cell density in cultivation and to track cell growth. The yeast Saccharomyces cerevisiae is one of the microorganisms most used in industry, and the OD600 values are frequently adopted as the indicator of yeast cell density, according to the Beer–Lambert law. Because the OD600 value is based on turbidity measurement, the Beer–Lambert law can be applied only for microbial cultivation with low cell densities. The proportio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 21 publications
1
8
0
Order By: Relevance
“…From the data presented in Fig. 2, it is noted that the yeast population has an average cell diameter between 5 and 5.5 μm, approximately, which corroborates with data from the literature (Fukuda, 2023). For yeast quantification with this technique, the interval of 3 to 11 μm was arbitrarily selected.…”
Section: Resultssupporting
confidence: 89%
“…From the data presented in Fig. 2, it is noted that the yeast population has an average cell diameter between 5 and 5.5 μm, approximately, which corroborates with data from the literature (Fukuda, 2023). For yeast quantification with this technique, the interval of 3 to 11 μm was arbitrarily selected.…”
Section: Resultssupporting
confidence: 89%
“…This finding highlights the potential of our system in a multitude of biological applications that involve the measurement of cell size. 41–44…”
Section: Discussionmentioning
confidence: 99%
“…40 Considering these associations, our system's capacity to measure cell size in yeast cultures presents a multitude of potential applications in the field of cell biology. [41][42][43][44]…”
Section: Impedance Measurementsmentioning
confidence: 99%
“…Samples (1 mL) were collected at 5, 30, 60, and 120 min. SC concentration was determined by measuring the optical density at 600 nm using a GE Healthcare UV-Vis spectrophotometer Ultrospec7000 (Little Chalfont, UK) [ 34 ]. SC concentration was determined based on the optical density of the suspension formed by the release of SC from the SC-loaded nanofiber dressing.…”
Section: Methodsmentioning
confidence: 99%