1967
DOI: 10.1152/jappl.1967.22.4.836
|View full text |Cite
|
Sign up to set email alerts
|

Apparatus for study of ventricular function and metabolism in the isolated perfused rat heart.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0
11

Year Published

1977
1977
2011
2011

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 90 publications
(32 citation statements)
references
References 0 publications
0
21
0
11
Order By: Relevance
“…Weight and tail cuff blood pressure were recorded weekly during the 7-week treatment period. Figure 1 illustrates the isolated isovolumic working rat heart preparation which has been previously described in detail (Fallen et al, 1967b;Apstein et al, 1977). Rats were injected intraperitoneally with 1-1.5 ml pentobarbital (15 mg/ml) and the thorax was rapidly opened.…”
Section: Methodsmentioning
confidence: 99%
“…Weight and tail cuff blood pressure were recorded weekly during the 7-week treatment period. Figure 1 illustrates the isolated isovolumic working rat heart preparation which has been previously described in detail (Fallen et al, 1967b;Apstein et al, 1977). Rats were injected intraperitoneally with 1-1.5 ml pentobarbital (15 mg/ml) and the thorax was rapidly opened.…”
Section: Methodsmentioning
confidence: 99%
“…The signals from the force transducer were recorded on an oscillograph and the data expressed as 'force of contraction'. The force of contraction of the heart was also recorded in isovolumic conditions by implanting a water-filled vinyl balloon into the left ventricle according to the method described by Fallen, Elliott & Gorlin (1967); in this preparation the balloon was connected to a pressure transducer (Statham P23 Db).…”
Section: Methodsmentioning
confidence: 99%
“…Исследования проведены на модели изолированного изово люмически сокращающегося сердца белых беспородных крыс по методу E. L. Fallen et al (1967) [3]. Было проведено две серии экс периментов.…”
Section: материал и методыunclassified
“…Ла тексный баллончик соединяли с датчиком монитора Mindray MEC 1200 для регистрации давления в левом желудочке. На осно вании графического материала рассчитывали комплекс силовых (систолическое, диастолическое и развиваемое давление) и скоро стных (+ dp/dt max -максимальная скорость увеличения и -dp/dt max -максимальная скорость снижения внутрижелудочко вого давления), а также дефект диастолы, позволявшие оценивать сократительную функцию сердца [3].…”
Section: материал и методыunclassified