1986
DOI: 10.1051/rphysap:019860021012083300
|View full text |Cite
|
Sign up to set email alerts
|

Apodization effects in Fourier transform infrared difference spectra

Abstract: Dans le cas de bandes intenses des artefacts dus au processus d'apodisation peuvent apparaître dans les spectres infrarouges obtenus par transformée de Fourier. Ces effets ont déjà été étudiés sur des spectres obtenus par différence pour des fonctions d'apodisation de type boxcar ou triangulaire. Ce travail présente des simulations numériques réalisées avec une fonction d'apodisation de type Happ-Genzel couramment employée dans les instruments modernes. Pour comparer les performances des fonctions d'appareil d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 10 publications
0
14
0
Order By: Relevance
“…The spectra were obtained at a resolution of 4 cm À1 by co-adding 32 interferograms. A Happ-Genzel apodization function (Bretzlaff & Bahder, 1986) was applied prior to Fourier transformation. Each sample was measured in triplicate.…”
Section: Infrared Analysismentioning
confidence: 99%
“…The spectra were obtained at a resolution of 4 cm À1 by co-adding 32 interferograms. A Happ-Genzel apodization function (Bretzlaff & Bahder, 1986) was applied prior to Fourier transformation. Each sample was measured in triplicate.…”
Section: Infrared Analysismentioning
confidence: 99%
“…The interferometer mirror velocity may also have an effect on SNR 3 . Weighting the interferogram with an apodization function will also contribute to a reduction in SNR, as this smoothing effect can incorporate spectral artifacts while one is attempting to optimize the information contained 93 . In general, the square root of the number of co-additions is proportional to the SNR, and therefore an increased number will enhance the SNR 94 .…”
Section: Introductionmentioning
confidence: 99%
“…Triangular apodization function was chosen, which leads to the diffraction contours of the lines [18]. For spectroscopic analysis, the exhaust gases from the plasma-chemical reactor have passed through 5.7 -centimeter cuvette, which was previously heated up to 90 o C in order to prevent condensation of water and alcohol vapors.…”
Section: Methodsmentioning
confidence: 99%