Abstract: Tumor therapy with light ion beams like Carbon out of a synchrotron is a topical accelerator application. In all designs the layout of the injector linac is an important factor with respect to construction and operation costs as well as to the operation performance of such a medical facility. Two alternative linac approaches which keep the number of components and setting parameters as low as possible are discussed. In both cases the Interdigital Htype drift tube structure is used for acceleration of C 4+ ions… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…A comparison between KONUS and APF layouts was reported in Ref. [35]. APF's advantage is the missing need of magnetic lenses, which reduces structure costs by about 30%.…”
Section: Comparison Between Konus Apf and Equusmentioning
confidence: 99%
“…A comparison between KONUS and APF layouts was reported in Ref. [35]. APF's advantage is the missing need of magnetic lenses, which reduces structure costs by about 30%.…”
Section: Comparison Between Konus Apf and Equusmentioning
confidence: 99%
“…The examples of the proposed modeling system and description of the used codes are given below. The initial data for modeling can be found in (Schlitt and Ratzinger, 1998;Minaev, Ratzinger and Schlitt, 1999;Angert et al, 1991;Angert et al, 1990;Gikal, 2013). The optimization of the beam characteristics on injector output depends on the optimization of separate parts of an injector; however, to achieve this mathematical control theory is not always suitable.…”
Section: Velocities Of the Ions Of Different Types Injectedmentioning
confidence: 99%
“…12 and C 6+ 12 ions was considered in papers (Schlitt and Ratzinger, 1998;Minaev et al, 1999) with respect to the German proposal for the HIT medical facility. Because the yield of C 6+…”
Section: Particle In Cell Simulationsmentioning
confidence: 99%
“…In the history, several different types of APF have been designed and constructed. [7][8] [9] [10] [11] Due to its relative weak focusing strength, a simple FODO type APF would be unsuitable for us. Also, as we consider the transmission efficiency as well as emittance suppression, an Iwata type APF become the best choice.…”
Section: The Principle Of the Dtl Designmentioning
confidence: 99%