2014
DOI: 10.1016/j.athoracsur.2014.05.092
|View full text |Cite
|
Sign up to set email alerts
|

Aortic Valve Replacement Through Right Anterior Minithoracotomy: Can Sutureless Technology Improve Clinical Outcomes?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

6
92
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 78 publications
(99 citation statements)
references
References 30 publications
(33 reference statements)
6
92
1
Order By: Relevance
“…However, owing to longer cross-clamp times and cardiopulmonary bypass times caused by the higher grade of complexity of the procedure,15 these approaches did not gain wide popularity, although even the use of various pericardial and porcine stentless valves proved to be possible through ministernotomy 16. Meanwhile, the Perceval Sutureless valve (Sorin/LivaNova Group, Saluggia, Italy), the EDWARDS INTUITY Elite (Edwards Lifesciences, Corp, Irvine, CA USA), and the Medtronic 3F Enable Bioprosthesis (Medtronic, Inc, Minneapolis, MN USA) have proven their suitability for different minimally invasive approaches to reduce aortic cross-clamp time in a prospective, nonrandomized trial17 and one prospective randomized study,18 thus reducing perioperative risk of the patients in nonrandomized trials 19,20. A recent systematic review and meta-analysis on 12 studies using Perceval Sutureless valve, Medtronic 3F Enable, or EDWARDS INTUITY confirmed that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and cardiopulmonary bypass time compared to conventional approaches 21.…”
mentioning
confidence: 99%
“…However, owing to longer cross-clamp times and cardiopulmonary bypass times caused by the higher grade of complexity of the procedure,15 these approaches did not gain wide popularity, although even the use of various pericardial and porcine stentless valves proved to be possible through ministernotomy 16. Meanwhile, the Perceval Sutureless valve (Sorin/LivaNova Group, Saluggia, Italy), the EDWARDS INTUITY Elite (Edwards Lifesciences, Corp, Irvine, CA USA), and the Medtronic 3F Enable Bioprosthesis (Medtronic, Inc, Minneapolis, MN USA) have proven their suitability for different minimally invasive approaches to reduce aortic cross-clamp time in a prospective, nonrandomized trial17 and one prospective randomized study,18 thus reducing perioperative risk of the patients in nonrandomized trials 19,20. A recent systematic review and meta-analysis on 12 studies using Perceval Sutureless valve, Medtronic 3F Enable, or EDWARDS INTUITY confirmed that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and cardiopulmonary bypass time compared to conventional approaches 21.…”
mentioning
confidence: 99%
“…The reliability of the Perceval sutureless bioprosthesis for aortic valve replacement has been already demonstrated . Initially, this valve prosthesis was implanted mostly in very elderly or in those patients with severe comorbidities.…”
Section: Discussionmentioning
confidence: 99%
“…Sutureless aortic valve bioprostheses have been developed to overcome the inherent increased risk of surgical AVR by reducing the aortic cross‐clamping time. The Perceval sutureless bioprosthesis (LivaNova Biomedica Cardio Srl, Saluggia, Italy) demonstrated excellent immediate results in patients at intermediate operative risk . However, hemodynamics of this valve prosthesis has been described in vivo only at rest and, to the best of our knowledge, there are no data on the hemodynamic performance of Perceval sutureless bioprosthesis under high workload conditions at mid‐term follow‐up.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with traditional prosthesis implantation via RAMT, the transition to a sutureless valve resulted in shorter crossclamp and bypass times. 4 …”
mentioning