2016
DOI: 10.1016/j.jvs.2015.07.099
|View full text |Cite|
|
Sign up to set email alerts
|

Aortic neck evolution after endovascular repair with TriVascular Ovation stent graft

Abstract: No aortic neck dilation occurred in this series at CT scan after a minimum 24-month follow-up. This may suggest that aortic neck evolution is not associated with EVAR at midterm follow-up when an endograft with no chronic outward radial force is implanted.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
28
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 62 publications
(29 citation statements)
references
References 21 publications
(17 reference statements)
1
28
0
Order By: Relevance
“…This is a significant difference relative to the Ovation iX, in which the sealing ring starts at 10 mm and centers at 13 mm ( Fig 1). 8 Other design improvements with Alto include the addition of an integrated compliant balloon (Fig 2). A marker on the proximal balloon is used to indicate the location of the sealing ring.…”
Section: Methodsmentioning
confidence: 99%
“…This is a significant difference relative to the Ovation iX, in which the sealing ring starts at 10 mm and centers at 13 mm ( Fig 1). 8 Other design improvements with Alto include the addition of an integrated compliant balloon (Fig 2). A marker on the proximal balloon is used to indicate the location of the sealing ring.…”
Section: Methodsmentioning
confidence: 99%
“…Similarly, with the use of the Ovation endograft, there was no dilatation of the aortic neck at 2-year follow-up in 89 patients. This is again due to the mechanism of the graft, which does not have a chronic outward radial force (sealing is obtained by polymer filled rings as opposed to self-expanding stent-grafts) [20]. Two-year follow-up results on 36 patients showed no AAA rupture, stent fracture or migration, and no type I, III, or IV endoleak.…”
Section: Device Planningmentioning
confidence: 95%
“…As well as the balloon-expandable stents, the sealing rings of the Ovation Prime device do not place chronic outward force on the aorta. Up to today, 4-year data from the premarket approval application for the Ovation device have revealed stability of the seal zone without aortic neck dilatation, migration, or proximal endoleak evolution in 100% of cases [20].…”
Section: Endograft Design and Aortic Neck Dilatationmentioning
confidence: 99%