2019
DOI: 10.1016/j.cardfail.2019.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Aortic Insufficiency and Hemocompatibility-related Adverse Events in Patients with Left Ventricular Assist Devices

Abstract: Aim: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. Methods and Results: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 18 publications
(26 reference statements)
0
19
0
Order By: Relevance
“…Doppler echocardiography of the outflow graft was performed via a modified right parasternal window. The diastolic acceleration slopes were measured and the regurgitant fraction (RF) was calculated using the previously detailed formula: (diastolic acceleration slope + 0.5) × 100/165.4 2,4,7 . Three consecutive RFs were calculated and averaged.…”
Section: Methodsmentioning
confidence: 99%
“…Doppler echocardiography of the outflow graft was performed via a modified right parasternal window. The diastolic acceleration slopes were measured and the regurgitant fraction (RF) was calculated using the previously detailed formula: (diastolic acceleration slope + 0.5) × 100/165.4 2,4,7 . Three consecutive RFs were calculated and averaged.…”
Section: Methodsmentioning
confidence: 99%
“…51 The risk of developing significant AI is increased among those with preexisting aortic regurgitation and once extended augments the rate of mortality together with the incidence of hemocompatibility-related adverse events. 52,53 Accepted surgical techniques to rectify AI in patients…”
Section: Aortic Insufficiencymentioning
confidence: 99%
“…Using these novel methods, many LVAD patients may have significant aortic insufficiency before clinical symptomology develops. Generally, the only definitive therapies are valve replacement or urgent heart transplantation [ 55 ].…”
Section: Hemodynamic Patterns By Disease Processmentioning
confidence: 99%
“… Pulse-Doppler echocardiography obtained at the outflow graft of left ventricular assist device (reused with permission [ 55 ]).The regurgitant fraction is estimated using the slope of diastolic acceleration (yellow bar). ( A ) no aortic insufficiency; ( B ) severe aortic insufficiency.…”
Section: Figurementioning
confidence: 99%