2021
DOI: 10.3390/diagnostics11050751
|View full text |Cite
|
Sign up to set email alerts
|

Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Abstract: (1) Background: We performed this study to evaluate the agreement between novel automated software of three-dimensional transesophageal echocardiography (3D-TEE) and multidetector computed tomography (MDCT) for aortic annular measurements of preprocedural transcatheter aortic valve replacement (TAVR); (2) Methods: PubMed, EMBASE, Web of Science, and Cochrane Library (Wiley) databases were systematically searched for studies that compared 3D-TEE and MDCT as the reference standard for aortic annular measurement … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 67 publications
0
9
0
1
Order By: Relevance
“…Yet, despite its clear advantages, MDCT requires administration of a contrast medium and therefore may not be suitable for patients with renal impairment or contrast allergies 13,14 . In such cases, 3‐dimensional TOE could be used as a viable alternative, with recent evidence showing that it correlates well with MDCT when assessing the aortic annulus parameters 64,65 …”
Section: Preprocedural Evaluation Of Patient Suitability For Tavrmentioning
confidence: 99%
See 1 more Smart Citation
“…Yet, despite its clear advantages, MDCT requires administration of a contrast medium and therefore may not be suitable for patients with renal impairment or contrast allergies 13,14 . In such cases, 3‐dimensional TOE could be used as a viable alternative, with recent evidence showing that it correlates well with MDCT when assessing the aortic annulus parameters 64,65 …”
Section: Preprocedural Evaluation Of Patient Suitability For Tavrmentioning
confidence: 99%
“… 13 , 14 In such cases, 3‐dimensional TOE could be used as a viable alternative, with recent evidence showing that it correlates well with MDCT when assessing the aortic annulus parameters. 64 , 65 …”
Section: Preprocedural Evaluation Of Patient Suitability For Tavrmentioning
confidence: 99%
“…Pooled correlation coefficients between 3D-TEE and MDCT annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were strong: 0.89 [95% confidence interval (CI): 0.84–0.92], 0.88 (95% CI: 0.83–0.92), 0.87 (95% CI: 0.77–0.93), 0.87 (95% CI: 0.77–0.93), 0.79 (95% CI: 0.64–0.87), and 0.75 (95% CI: 0.61–0.84) (overall P<0.0001). The study implied that 3D-TEE, using novel software tools, is feasible to MDCT for annulus sizing in clinical practice ( 15 ). Currently, CT scan-derived root and annular dimensions are the standard of care in the United States (US) of America.…”
Section: Tavr Sizingmentioning
confidence: 99%
“…73,74 Beyond that, transesophageal echocardiography (TEE) avoids thoracic and lung interference and the imaging is more precise, which improves the sensitivity and reliability of transthoracic ultrasound. By taking preoperative and intraoperative realtime measurements of cardiac structures, TEE may provide surgical guidance in congenital heart disease, 75 atrioventricular septal defects, 76,77 transcatheter aortic valve replacement (TAVR) 78 and left atrial appendage (LAA) closure, 79 and predict postoperative complications. 75,80 Further, real-time 3D-TEE optimizes the spatial and temporal resolution and enables an en face view, thereby significantly enhancing the visualization of a complex 3D structure.…”
Section: Echocardiographymentioning
confidence: 99%