2001
DOI: 10.1046/j.1365-2982.2001.00285.x
|View full text |Cite
|
Sign up to set email alerts
|

Antral motility measurements by magnetic resonance imaging

Abstract: Magnetic resonance imaging has been recently proposed as a promising, noninvasive technique to assess the motility of the gastric antrum. However, so far the reproducibility and dependence on test meal composition has not been evaluated. In this study, snapshot echo-planar magnetic resonance imaging was used to measure the frequency, propagation speed and percentage occlusion of antral contractions in 28 healthy volunteers. They were fed either liquid (n=12), mixed liquid/solid (n=8) or mixed viscous/solid (n=… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
76
1

Year Published

2004
2004
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 98 publications
(79 citation statements)
references
References 17 publications
2
76
1
Order By: Relevance
“…Based on a qualitative analysis of the experimental data, which show the development of a ring contraction with the narrowing of the lumen gut proximal to the metal bit, we can assume that it corresponds to the peak of the total force (1851 mN/cm) distribution observed in our results [4]. Our results fall in the range of experimentally measured velocity of the movement of intraluminal content (1-3 cm/s), which was observed in the studies of colonic motility in humans [8][9]. The model allows us to reproduce the effects of drugs affecting gut motility.…”
Section: Discussionsupporting
confidence: 53%
“…Based on a qualitative analysis of the experimental data, which show the development of a ring contraction with the narrowing of the lumen gut proximal to the metal bit, we can assume that it corresponds to the peak of the total force (1851 mN/cm) distribution observed in our results [4]. Our results fall in the range of experimentally measured velocity of the movement of intraluminal content (1-3 cm/s), which was observed in the studies of colonic motility in humans [8][9]. The model allows us to reproduce the effects of drugs affecting gut motility.…”
Section: Discussionsupporting
confidence: 53%
“…This approach has been shown to be reliable and reproducible. 28 The high signal within the stomach in this sequence depends on paramagnetic contrast agent within the food ingested. In this study, we chose a pudding as the high caloric base for the oral contrast agent; in vitro experiments had revealed the pudding to be brightest following addition of a paramagnetic contrast in a concentration of 1:200.…”
Section: Discussionmentioning
confidence: 99%
“…MRI has the potential to become an overall test to measure gastric emptying, volume change, and wall motion as a surrogate of contractile activity without radiation exposure (43,72,73,76,85,86,111). It also has the ability to separately assess the emptying of fat and water from the stomach (73).…”
Section: Other Technologies For Gastric Emptyingmentioning
confidence: 99%