2014
DOI: 10.1016/j.aca.2014.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Antigen detection based on background fluorescence quenching immunochromatographic assay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 19 publications
0
16
0
Order By: Relevance
“…The unconjugated quenching complexes migrated to absorbent pad. No fluorescence quenching occurred on fluorescein coated NC membrane between the TL and CL [185].…”
Section: Fluorescent Quenching Materialsmentioning
confidence: 86%
See 1 more Smart Citation
“…The unconjugated quenching complexes migrated to absorbent pad. No fluorescence quenching occurred on fluorescein coated NC membrane between the TL and CL [185].…”
Section: Fluorescent Quenching Materialsmentioning
confidence: 86%
“…The detection signal intensity of the TL increased with the increasing concentration of analyte [183]. The fluorescence quenching based LFAs has been used for ractopimine [184], Cr 3+ [183] and AFP [185] detection.…”
Section: Fluorescent Quenching Materialsmentioning
confidence: 99%
“…Upon reaching the test line, the remanent GNPs-labeled antibody not binding with AFM1 or CAP bound with the coated antigen of AFM1 or CAP to form the antigen-antibody-GNP complex that quenches the fluorescence on the test line. The content of test samples was correlated to the quenching of the fluorescence presented as the ratio of fluorescence on the test line to the background fluorescence ( F 1 / F 0 ) [10]. …”
Section: Methodsmentioning
confidence: 99%
“…The method has been used for the alpha fetoprotein in clinical practice. Unlike the conventional GICA assay, in the background fluorescence quenching immunochromatographic assay (bFQICA), the fluorescence donors are fluorescein that are precoated on the entire nitrocellulose membrane and quenching occurs between the gold particles and nitrocellulose membrane [10]. In this study, we firstly applied such technique in the food safety.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, some research groups [25][26][27][28][29][30] reported a novel uorescence-quenching ICS to improve the assay sensitivity. The uorescence donors used in the above study were mainly uo-rescein, uorescein-doped microspheres or Ru(phen) 3…”
mentioning
confidence: 99%