2015
DOI: 10.1016/j.ijporl.2015.05.037
|View full text |Cite
|
Sign up to set email alerts
|

Antibacterial effect of electrospun polycaprolactone/polyethylene oxide/vancomycin nanofiber mat for prevention of periprosthetic infection and biofilm formation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(16 citation statements)
references
References 22 publications
(23 reference statements)
0
14
0
2
Order By: Relevance
“…A rabbit otitis model examined the efficacy of a nanoporous middle ear implant coating releasing ciprofloxacin against P. aeruginosa (370). In another study, a guinea pig animal model combined with otoendoscopy, histology, and bone CT was used to examine the inhibitory effect of a vancomycin-eluting nanofiber mat against MRSA biofilms formed on ossicular prostheses and middle ear infections (371).…”
Section: Vertebrate Animal Modelsmentioning
confidence: 99%
“…A rabbit otitis model examined the efficacy of a nanoporous middle ear implant coating releasing ciprofloxacin against P. aeruginosa (370). In another study, a guinea pig animal model combined with otoendoscopy, histology, and bone CT was used to examine the inhibitory effect of a vancomycin-eluting nanofiber mat against MRSA biofilms formed on ossicular prostheses and middle ear infections (371).…”
Section: Vertebrate Animal Modelsmentioning
confidence: 99%
“…The antibacterial efficacy of the PEP-1-loaded scaffolds was tested against EC and SA bacteria. In the current study, an agar diffusion method was adapted from the references with a little modification [39,41,42,43]. Firstly, SA and EC bacteria were cultured two passages in LB-broth after cell thawing from frozen storage.…”
Section: Methodsmentioning
confidence: 99%
“…A number of studies have verified that the reagents and techniques used to create the vancomycin–impregnated membrane will not change vancomycin’s configuration or physical properties. 2326…”
Section: Methodsmentioning
confidence: 99%
“…A number of studies have verified that the reagents and techniques used to create the vancomycin-impregnated membrane will not change vancomycin's configuration or physical properties. [23][24][25][26] Electron microscopy and electrospinning parameters A PCL solution not containing vancomycin was used to prepare test membrane samples. This solution was added to the injector of an electrospinning machine, and electrospinning parameters (size of injection needle, receiving distance, and spinning voltage) were varied.…”
Section: Preparation Of a Resorbable Pcl Electrospun Fiber Membrane Cmentioning
confidence: 99%