2020
DOI: 10.1016/j.optlaseng.2020.106250
|View full text |Cite
|
Sign up to set email alerts
|

Anti-noise frequency estimation performance of Hanning-windowed energy centrobaric method for optical coherence velocimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…Aim to improve the optical path measurement accuracy, it is necessary to find the method of extracting the number of cycles of interference fringes that can realize high accuracy and non-integer cycle resolution. The method used in this paper is the energy spectrum gravity method based on the Hanning window [28,29]. High precision estimation of interference signal frequency f can be achieved by the following formula.…”
Section: Principle Of High-precision Optical Path Measurement Based O...mentioning
confidence: 99%
See 2 more Smart Citations
“…Aim to improve the optical path measurement accuracy, it is necessary to find the method of extracting the number of cycles of interference fringes that can realize high accuracy and non-integer cycle resolution. The method used in this paper is the energy spectrum gravity method based on the Hanning window [28,29]. High precision estimation of interference signal frequency f can be achieved by the following formula.…”
Section: Principle Of High-precision Optical Path Measurement Based O...mentioning
confidence: 99%
“…If the accurate frequency of the signal want to be calculated, select 2n + 1 points near the peak (usually n takes 3 ∼ 7) and calculate according to the above formula. By applying the Hanning window energy spectrum correction principle, the measurement accuracy of the optical path can be greatly improved to the nanometer or even subnanometer level [29].…”
Section: Principle Of High-precision Optical Path Measurement Based O...mentioning
confidence: 99%
See 1 more Smart Citation
“…For broadband lights, the group refractive index is defined as the ratio of the group velocity of lights in the vacuum and the velocity in the medium, while the refractive index is the ratio of the velocity of single wavelength light in the vacuum and the medium [4]. To address this issue, this paper presents a novel method that combines the HnWECM and OCT to measure the geometric thickness of the sample with high precision, without the influence of its group refractive index [5]. The accuracy and feasibility of our novel method were verified by comparing the thickness of the peeled-off self-lubricating fabric liner of the bearing, measured by our novel method and spiral micrometer.…”
Section: Introductionmentioning
confidence: 99%
“…Many researchers have investigated the interferences from spectral components, wideband noise, and other precision factors related to the estimated parameters [ 16 , 17 ]. This algorithm has fast speed and great accuracy of frequency calculation, so it has been applied to engineering after improvement [ 18 ]. However, the correction accuracy is too dependent on the symmetric window function and is easily affected by white Gaussian noise (WGN).…”
Section: Introductionmentioning
confidence: 99%