2012
DOI: 10.1093/humrep/des260
|View full text |Cite
|
Sign up to set email alerts
|

Anti-Mullerian hormone: poor assay reproducibility in a large cohort of subjects suggests sample instability

Abstract: S. Roberts is supported by the NIHR Manchester Biomedical Research Centre.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
101
0
5

Year Published

2013
2013
2018
2018

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 152 publications
(112 citation statements)
references
References 30 publications
6
101
0
5
Order By: Relevance
“…One challenge has been that the IOT assays produced AMH concentrations up to 40 % higher than DSL, making interpretation of the absolute values difficult [28,30]. Studies that produced cut-off values and nomograms must be scrutinized for the assay used prior to applying the information, regardless of how compelling the data appears, to the reader's own clinical situation [1,31]. Currently, the above listed labs DSL and IOT have been acquired by Beckman Coulter, and a single patented assay for testing AMH (AMH Gen II) is now available.…”
Section: Discussionmentioning
confidence: 99%
“…One challenge has been that the IOT assays produced AMH concentrations up to 40 % higher than DSL, making interpretation of the absolute values difficult [28,30]. Studies that produced cut-off values and nomograms must be scrutinized for the assay used prior to applying the information, regardless of how compelling the data appears, to the reader's own clinical situation [1,31]. Currently, the above listed labs DSL and IOT have been acquired by Beckman Coulter, and a single patented assay for testing AMH (AMH Gen II) is now available.…”
Section: Discussionmentioning
confidence: 99%
“…These ELISA assays are inevitably limited by their technical characteristics that limit their up scaling for routine clinical chemistry laboratories. Furthermore the Beckman Coulter Generation II assay exhibited complement interference in fresh samples requiring a modified protocol to be developed, introducing a further step that would complicate robotic instrumentation (10,11).…”
Section: Introductionmentioning
confidence: 99%
“…28 AFC on the other hand, is the sum of antral follicles on both ovaries as visualized through transvaginal ultrasonography. 3 Histologically, the number of antral follicles visualized appear to correlate with the number of primordial follicles at any age.…”
Section: Reliabilitymentioning